Page 1
Schiffsuhr CHROM 232mm Mod. 20804/IP ENI v3 Marine clock CHROME 232mm Art.-no. CW850346 Eine zeitlos schöne Schiffsuhr! Die elegante Schiffsuhr wird in einem hochglanzverchromten Messinggehäuse geliefert. A timeless beauty marine clock! The elegant marine clock with high-gloss polished brass case chrome plated and glass frame.
Page 2
Schiffsuhr CHROM 232mm Mod. 20804/IP ENI v3 Marine clock CHROME 232mm Art.-no. CW850346 Verfügbare Uhrwerktechnologien Available clock movement technologies Modell Zeiger Uhrwerktechnologie Model Hands Movement technology 2 (Std./Min.) Ethernet Nebenuhr selbstrichtend PoE (Power over Ethernet) 20804/IP 2 (h/m) Ethernet secondary clock self-setting PoE (Power over Ethernet)
Page 3
Schiffsuhr CHROM 232mm Mod. 20804/IP ENI v3 Marine clock CHROME 232mm Art.-no. CW850346 Montage- und Inbetriebnahmeanleitung für Nebenuhrwerke Typ: T Dieses nach neustem Stand Technik entwickelte Nebenuhrwerk kann mit 12, 24, 48 oder 60V DC polarisierten Minutenimpulsen betreiben werden. Es ist sowohl für Innen- als auch für Außenuhren mit geschützten Zeigern bis zu einem...
Page 4
Schiffsuhr CHROM 232mm Mod. 20804/IP ENI v3 Marine clock CHROME 232mm Art.-no. CW850346 Assembly and commissioning instructions for secondary clock movements’ type: T This state-of-the-art secondary clock movement can run on polarizing minute impulses of 12, 24, 48 or 60V DC. It is suitable for indoor clocks as well as for outdoor clocks with protected hands with a diameter of 80cm at maximum.
Installation 1.1 Configuration The Wempe Ethernet Slaveclock consists of two parts: The mechanical clock and the electronic Ethernet Network Interface (ENI). The arms of the slave clock are self adjusting and pre setted already. Normally no further administration or commissioning is necessary. If other than the default pre settings are desired, the ENI can be administrated using the ENI web interface.
1.3.1 NTP Server Select Master clock Connection Type "WEMPE Master clock 20102, NTP server" Enter the static IP address of a primary NTP server and, if desired, a secondary NTP server. This step can be omitted, if the addresses are supplied by a DHCP server.
WEMPE ENI secondary clocks interface 2 Operating controls During normal clock operation, there is no need to access to the operating controls. In case of troubleshooting the controls can be accessed after opening the ENI's housing. 2.1 Switches Lights Service...
Page 9
WEMPE ENI secondary clocks interface 2.2 Lights All lights are activated only if the so named switch (see above) is set to "ON"! Blue LED: "Power" Shows, that the internal power regulation is up. Wether the ENI is powered from an ethernet switch (PoE) or an external 24V DC supply, the power is good.
WEMPE ENI secondary clocks interface 3 Web interface The graphical user interface (GUI) provides status information and configuration items. It's built in as a web interface (aka HTTP server). It can be accessed from a PC running any operating system connected to the same network via almost any (recent) web browser.
WEMPE ENI secondary clocks interface 4 Troubleshooting This requires physical access to the ENI device. Open the housing and set the "Lights" switch to "ON". problem possible cause/solution The blue LED "Power" is off. Check the physical connection between ENI and PoE switch, all cables and plugs.
Page 12
Check any blocking features (firewall etc.) at every routing Clock hands keep showing 12:00, device between ENI and NTP server(s). Connection type is "WEMPE Check the NTP server at the configured IP address(es) are Masterclock 20102, NTP server.