Curtis G3 Gemini IntelliFresh GEMTIF10A2000 User Manual page 43

Coffee brewing system
Table of Contents

Advertisement

TROUBLESHOOTING GUIDE
Satellite Does Not Heat
NOTE
reheat cold coffee.
1
(replace the controller).
Check to make sure that the warmer is not turned off. See the PROGRAMMING GUIDE section.
2
3
Check to see if the IntelliFresh LED on the front of the satellite comes on at the beginning of the brew cycle.
If neither the LED nor the warmer come on, then it can be assumed that there is no power to the satellite.
Make sure that power is being supplied to the IntelliFresh (IF) connector on the brewer when the BREW
present at the connector, check the connector contacts. If power is not present at the IF connector, trace the
circuit back to the control module to see if it is supplying power to the IF connector.
4
Check the contacts on the satellite IF connector to make sure that they are making good contact with the
connector on the brewer.
5
LED Does Not Light (Warmer OK)
1
2
If the LED is OK, suspect the controller.
INTELLIFRESH SATELLITE, TROUBLESHOOTING GUIDE
ELECTRICAL SCHEMATIC. If power is
TG13
092217A

Advertisement

Table of Contents
loading

Table of Contents