Integration into Modbus Systems
Fan Speed (all the units)
Remote Lock (all the units)
Table 3. Outdoor unit registers
Register name
OU Compressor 1 Frequency
OU Compressor 2 Frequency
OU Heat Exchange low 1 temperature (x10)
OU Heat Exchange low 2 temperature (x10)
OU Heat Exchange low 3 temperature (x10)
OU Heat Exchange low 4 temperature (x10)
OU Heat exchange high 1 temperature (x10)
OU Heat exchange high 2 temperature (x10)
OU Heat exchange high 3 temperature (x10)
OU Heat exchange high 4 temperature (x10)
OU Unit temperature (x10)
OU Discharge pipe temperature 1 (x10)
OU Discharge pipe temperature 2 (x10)
OU Crankcase 1 temperature (x10)
OU Crankcase 2 temperature (x10)
OU Compressor current 1 (x10)
OU Compressor current 2 (x10)
OU High pressure (x100)
OU Low pressure (x100)
Table 4. Indoor unit registers
Register name
Communication Status
On/Off
Operation Mode
Temperature Setpoint (x10)
USER MANUAL Version 1.2.7
0: Low
1: Mediu
2: High
3: Powerful
1: Lock
0-Unlock
Possible values
Modbus address
0 .. 255 Hz
(OU address[0 .. 127]*20)+4000+1
0 .. 255 Hz
(OU address[0 .. 127]*20)+4000+2
°C / °F
(OU address[0 .. 127]*20)+4000+3
°C / °F
(OU address[0 .. 127]*20)+4000+4
°C / °F
(OU address[0 .. 127]*20)+4000+5
°C / °F
(OU address[0 .. 127]*20)+4000+6
°C / °F
(OU address[0 .. 127]*20)+4000+7
°C / °F
(OU address[0 .. 127]*20)+4000+8
°C / °F
(OU address[0 .. 127]*20)+4000+9
°C / °F
(OU address[0 .. 127]*20)+4000+10
°C / °F
(OU address[0 .. 127]*20)+4000+11
°C / °F
(OU address[0 .. 127]*20)+4000+12
°C / °F
(OU address[0 .. 127]*20)+4000+13
°C / °F
(OU address[0 .. 127]*20)+4000+14
°C / °F
(OU address[0 .. 127]*20)+4000+15
Amperes
(OU address[0 .. 127]*20)+4000+16
Amperes
(OU address[0 .. 127]*20)+4000+17
MPa
(OU address[0 .. 127]*20)+4000+18
MPa
(OU address[0 .. 127]*20)+4000+19
Possible values
0: No Error
(IU address[0 .. 127]*20)+1
1: Error
0: Off,
(IU address[0 .. 127]*20)+2
1: On
0: Cool
(IU address[0 .. 127]*20)+3
1: Heat
2: Fan
3: Auto
4: Dry
Celsius: 16 .. 30°C
(IU address[0 .. 127]*20)+4
Fahrenheit: 60 .. 86°F
Mitsubishi Heavy Industries VRF with KNX, Serial and IP support
2999
R, W
3000
R, W
R/W
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Modbus address
R/W
R
R, W
R, W
R, W
Page 23 of 36