  • Page 1 ENGLISH Hisense VRF with KNX, Serial and IP support IN770AIR00XO000 GATEWAY USER MANUAL Version 1.0.3 Publication date 2023-07-20...
  • Page 2 The information in this document shall therefore not be construed as a commitment on the part of HMS Networks and is subject to change without notice. HMS Networks makes no commitment to update or keep current the information in this document.
  • Page 3: Table Of Contents

    Hisense VRF with KNX, Serial and IP support Table of Contents 1. Description and Order Codes ..................... 1 2. Licensing ..........................2 3. General Information ........................ 3 3.1. Intended Use of the User Manual ..................3 3.2. General Safety Information ....................3 3.3.
  • Page 4: Description And Order Codes

    Description and Order Codes Hisense VRF with KNX, Serial and IP support 1. Description and Order Codes IN770AIR00xO000 Gateway. Modbus®, KNX®, BACnet®, and Home Automation® gateway for Hisense® air conditioning systems. ORDER CODE LEGACY ORDER CODE INBACHIS016O000 INBACHIS064O000 IN770AIR00xO000 INKNXHIS016O000 INKNXHIS064O000 INMBSHIS016O000 INMBSHIS064O000 The x stands for S, M, or L, depending on the license you have purchased.
  • Page 5: Licensing

    Hisense VRF with KNX, Serial and IP support Licensing 2. Licensing Distribution license(s) for the IN770AIR00xO000 gateway: Maximum AC units Order Code License Indoor units Outdoor units IN770AIR00SO000 Small IN770AIR00MO000 Medium NOTE The order code may vary depending on the product seller and the buyer's location. Page 2 of 41 USER MANUAL Version 1.0.3...
  • Page 6: General Information

    General Information Hisense VRF with KNX, Serial and IP support 3. General Information 3.1. Intended Use of the User Manual This manual contains the main features of this Intesis gateway and the instructions for its appropriate installation, configuration, and operation. The contents of this manual should be brought to the attention of any person who installs, configures, or operates this gateway or any associated equipment.
  • Page 7 Hisense VRF with KNX, Serial and IP support Admonition Messages and Symbols NOTE Additional information which may facilitate installation and/or operation. Helpful advice and suggestions. NOTICE Remarkable Information. Page 4 of 41 USER MANUAL Version 1.0.3...
  • Page 8: Overview

    Overview Hisense VRF with KNX, Serial and IP support 4. Overview This document describes the available applications for this IN770AIR00xO000 gateway. Hisense VRF HVAC systems to: Modbus TCP and RTU KNX TP BACnet/IP or MS/TP Home Automation IMPORTANT This document assumes that the user is familiar with these technologies. Figure 1.
  • Page 9: Inside The Package

    Hisense VRF with KNX, Serial and IP support Inside the Package Figure 3. Integration of Hisense AC systems into KNX installations Figure 4. Integration of Hisense AC systems into Home Automation installations 4.1. Inside the Package Items included: • Intesis IN770AIR00xO000 Gateway •...
  • Page 10: Gateway General Functionality

    Gateway General Functionality Hisense VRF with KNX, Serial and IP support • DIN rail and wall mounting case. • Accredited with the main certifications for electronic equipment. • Multiple ports for serial and TCP/IP communication: – Green pluggable terminal block for EIA-485 (3 poles) –...
  • Page 11: Hardware

    Hisense VRF with KNX, Serial and IP support Hardware 5. Hardware 5.1. Mounting IMPORTANT Before mounting, please ensure that the chosen installation place preserves the gateway from direct solar radiation, water, high relative humidity, or dust. IMPORTANT Maximum mounting height: below 2 meters (6.5 feet). NOTE Mount the gateway on a wall or over a DIN rail.
  • Page 12 Mounting Hisense VRF with KNX, Serial and IP support DIN rail mounting Keep the clips down in their original position. Fit the gateway’s top side clips in the upper edge of the DIN rail. Use a screwdriver or similar to pull the bottom clip down. Fit the low side of the gateway in the DIN rail and let the clip switch back to its original position, locking the gateway to the rail.
  • Page 13: Connection

    Hisense VRF with KNX, Serial and IP support Connection 5.2. Connection CAUTION Disconnect all systems from the power source before manipulating and connecting them to the gateway. IMPORTANT Keep communication cables away from power and ground wires. 5.2.1. Gateway Connectors Figure 5.
  • Page 14 Connection Hisense VRF with KNX, Serial and IP support NOTE Mount the gateway in the desired installation site before wiring. IMPORTANT Use solid or stranded wires (twisted or with ferrule). Wire cross-section/gauge for all wire connectors: • One core: 0.2 .. 2.5 mm (24 ..
  • Page 15: Common Connections

    Hisense VRF with KNX, Serial and IP support Connection 5.2.2. Common Connections 5.2.2.1. Connecting the Gateway to the Power Supply The power supply connector is a green pluggable terminal block (3 poles) labeled as Power. IMPORTANT • Use SELV-rated NEC class 2 or limited power source (LPS) power supply. •...
  • Page 16: Connection Procedure For Modbus

    Connection Hisense VRF with KNX, Serial and IP support 5.2.3. Connection Procedure for Modbus NOTE Remember to consult the Common Connections (page 12). For Modbus TCP: 1. Connect the Modbus TCP Ethernet cable to the gateway's Ethernet Port. IMPORTANT Use a straight Ethernet UTP/FTP CAT5 or higher cable. IMPORTANT If communicating through the LAN of the building, contact the network administrator and make sure traffic on the used port is allowed through all LAN paths.
  • Page 17 Hisense VRF with KNX, Serial and IP support Connection 2. Use the supplied USB Mini-B type to A type cable to connect the gateway, through its USB port, to a PC to configure it with Intesis MAPS. NOTE For Modbus RTU only, you can use the Ethernet Port to connect the gateway and the PC instead. NOTICE Find all you need to know about the gateway configuration and Intesis MAPS in the Intesis MAPS...
  • Page 18: Connection Procedure For Knx

    Connection Hisense VRF with KNX, Serial and IP support 5.2.4. Connection Procedure for KNX NOTE Remember to consult the Common Connections (page 12). 1. Connect the KNX TP communication cable to the gateway's KNX port. IMPORTANT Observe polarity. 2. Use the supplied USB Mini-B type to A type cable to connect the gateway, through its USB port, to a PC to configure it with Intesis MAPS.
  • Page 19: Connection Procedure For Bacnet

    Hisense VRF with KNX, Serial and IP support Connection 5.2.5. Connection Procedure for BACnet NOTE Remember to consult the Common Connections (page 12). For BACnet/IP: 1. Connect the BACnet/IP Ethernet cable to the gateway's Ethernet Port. The correct cable to use depends on where the gateway is connected: •...
  • Page 20 Connection Hisense VRF with KNX, Serial and IP support 2. Use the supplied USB Mini-B type to A type cable to connect the gateway, through its USB port, to a PC to configure it with Intesis MAPS. NOTE For BACnet MS/TP only, you can use the Ethernet Port to connect the gateway and the PC instead.
  • Page 21: Connection Procedure For Home Automation

    Hisense VRF with KNX, Serial and IP support Connection 5.2.6. Connection Procedure for Home Automation NOTE Remember to consult the Common Connections (page 12). 1. Connect the Home Automation Ethernet cable to the gateway's Ethernet Port. IMPORTANT Use a straight Ethernet UTP/FTP CAT5 or higher cable. IMPORTANT If communicating through the LAN of the building, contact the network administrator and make sure traffic on the used port is allowed through all LAN paths.
  • Page 22: Gateway Layout

    Gateway Layout Hisense VRF with KNX, Serial and IP support 5.3. Gateway Layout Find in this image below the disposition of various hardware elements in the gateway. Figure 6. Gateway layout The following sections explain in more detail each element: LEDs, DIP switches, and the push button. USER MANUAL Version 1.0.3 Page 19 of 41...
  • Page 23: Led Indicators

    Hisense VRF with KNX, Serial and IP support LED Indicators 5.4. LED Indicators Table 1. LEDs location and behavior Cover Color Description Top side LED 1 (PWR) Green Power on (not programmable) LED 2 (ERR) Blinking: Hardware error Under frontal cover ① LED 3 Green 485 Tx (RS485 for BACnet or Modbus)
  • Page 24: Push Button

    Push Button Hisense VRF with KNX, Serial and IP support 5.6. Push Button Find the push button at the top side, between the KNX and the Ethernet connectors (figure Gateway layout (page 19)). NOTE The button is hidden and only accessible using a thin object like a paper clip. Common functionality: Reset factory settings Push the button.
  • Page 25: Technical Specifications

    Hisense VRF with KNX, Serial and IP support Technical Specifications 5.7. Technical Specifications Plastic, type PC (UL 94 V-0). Color: Light Grey. RAL 7035 Net dimensions (dxwxh): Millimeters: 90 x 106 x 58 mm / Inches: 3.5 x 4.2 x 2.3" Case Recommended space for installation (dxwxh): Millimeters: 130 x 115 x 100 mm / Inches: 5.1 x 4.5 x3.9"...
  • Page 26: Dimensions

    Dimensions Hisense VRF with KNX, Serial and IP support 5.8. Dimensions • Net dimensions (DxWxH) Millimeters: 90 x 106 x 58 mm Inches: 3.5 x 4.2 x 2.3" • Clear space for installation (DxWxH) Millimeters: 130 x 115 x 100 mm Inches: 5.1 x 4.5 x 3.9"...
  • Page 27: Available Applications

    Hisense VRF with KNX, Serial and IP support Available Applications 6. Available Applications 6.1. Integration into Modbus Systems 6.1.1. Modbus Registers NOTICE This part is common for Modbus RTU and TCP. Functions to read Modbus registers: • 03 Read Holding Registers. •...
  • Page 28 Integration into Modbus Systems Hisense VRF with KNX, Serial and IP support Register name Possible values Air louver 4 (all the units) 1: Set Air louver Position 4 Trigger Air louver 5 (all the units) 1: Set Air louver Position 5 Trigger Air louver 6 (all the units) 1: Set Air louver Position 6...
  • Page 29 Hisense VRF with KNX, Serial and IP support Integration into Modbus Systems Register name Possible values Modbus address formula Celsius: -63 .. 63°C LiquidPipe Temp. (x10°C) (IU address × 100) + 9 Celsius: -81 .. 145°F Unit Error code Error code (IU address ×...
  • Page 30 Integration into Modbus Systems Hisense VRF with KNX, Serial and IP support Register name Possible values Modbus address formula Consumption Total Cool Wh/KWh (IU address × 100) + 44 USER MANUAL Version 1.0.3 Page 27 of 41...
  • Page 31: Integration Into Knx Systems

    Hisense VRF with KNX, Serial and IP support Integration into KNX Systems 6.2. Integration into KNX Systems 6.2.1. KNX Signals The following tables list all available KNX signals for this gateway. NOTE Physical Address: The gateway supports (P/S) and (P/I/S) format levels. NOTICE Communication object flags: •...
  • Page 32 Integration into KNX Systems Hisense VRF with KNX, Serial and IP support Object name Possible values Flags Celsius: -50 .. 99 °C Status_Outdoor Air Temperature (°C) 9.001-DPT_Value_Temp (2byte) R, T Fahrenheit: -58 .. 210°F Celsius: 0 .. 200 °C Status_Compresor Top Temperature (°C) 9.001-DPT_Value_Temp (2byte) R, T Fahrenheit: 32 ..
  • Page 33 Hisense VRF with KNX, Serial and IP support Integration into KNX Systems Object name Possible values Flags Control_Cool mode 1: Set cool mode 1.001-DPT_Switch (1bit) Ri, W, U 1: Cool mode active Status_Cool mode 1.001-DPT_Switch (1bit) R, T 0: Cool mode not active Control_Fan mode 1: Set fan mode 1.001-DPT_Switch (1bit)
  • Page 34 Integration into KNX Systems Hisense VRF with KNX, Serial and IP support Object name Possible values Flags Thersholds: 0 .. 21 % 22 .. 36 % 37 .. 50 % Control_Vane position scaling 5.001-DPT_Scaling (1byte) Ri, W, U 51 .. 64 % 65 ..
  • Page 35 Hisense VRF with KNX, Serial and IP support Integration into KNX Systems Object name Possible values Flags Celsius: -63 .. 63 °C Status_Outlet Temperature 9.001-DPT_Value_Temp (2byte) R, T Fahrenheit: -81 .. 145°F Celsius: -63 .. 63 °C Status_GasPipe Temperature 9.001-DPT_Value_Temp (2byte) R, T Fahrenheit: -81 ..
  • Page 36 Integration into KNX Systems Hisense VRF with KNX, Serial and IP support Object name Possible values Flags 0: Off 1: Thermo Off Status_Operation condition 5.x (1byte) R, T 2: Thermo On 3: Alarm Celsius: -63 .. 63 °C Status_RC SW Temperature 9.001-DPT_Value_Temp (2byte) R, T Fahrenheit: -81 ..
  • Page 37: Integration Into Bacnet Systems

    Hisense VRF with KNX, Serial and IP support Integration into BACnet Systems 6.3. Integration into BACnet Systems NOTICE You can see the Protocol Implementation Conformance Statement (PICS) document on https:// www.intesis.com/docs/bacnet-client-pic-statement-770 6.3.1. BACnet Objects NOTICE This part is common for BACnet MS/TP and BACnet/IP. Input object types: •...
  • Page 38 Integration into BACnet Systems Hisense VRF with KNX, Serial and IP support Object name Possible values Object type Object instance OUXX_Total Real Comp. Freq. 0 .. 255 Hz 0-Analog Input (OU address × 25) + 20000 + 2 OUXX_Total Comp. Current 0 ..
  • Page 39 Hisense VRF with KNX, Serial and IP support Integration into BACnet Systems Object name Possible values Object type Object instance Celsius: -63 .. 63°C OXXUXX_LiquidPipe Temp. 0-Analog Input (IU address × 100) + 5 Fahrenheit: -81 .. 145°F OXXUXX_Unit Error code Error code 0-Analog Input (IU address ×...
  • Page 40 Integration into BACnet Systems Hisense VRF with KNX, Serial and IP support Object name Possible values Object type Object instance 0: Without RCS OXXUXX_RC SW Config 3-Binary Input (IU address × 100) + 8 1: With RCS OXXUXX_Consumption Yesterday_S Wh/KWh 0-Analog Input (IU address ×...
  • Page 41: Integration Into Home Automation Systems

    Hisense VRF with KNX, Serial and IP support Integration into Home Automation Systems 6.4. Integration into Home Automation Systems 6.4.1. Home Automation Signals The following tables list all available Home Automation signals for this gateway. NOTE • SET: Command used to control the indoor unit. It is sent by the client. •...
  • Page 42: Late Configuration: Change The Gateway's Protocol

    Late Configuration: Change the Gateway's Protocol Hisense VRF with KNX, Serial and IP support 7. Late Configuration: Change the Gateway's Protocol Reconfiguring the gateway with a different protocol is very easy: Connect the gateway to the PC and open the configuration tool Intesis MAPS. Select the new template you need.
  • Page 43: Error Codes

    Hisense VRF with KNX, Serial and IP support Error Codes 8. Error Codes NOTE These error codes are the same for all applications. Error Category Description Cause Code Activation of Protection Device (Float Activation of Float Switch (High Water Level in Drain Pan, Indoor unit Switch) Abnormality of Drain Pipe, Float Switch or Drain Pan)
  • Page 44 Error Codes Hisense VRF with KNX, Serial and IP support Error Category Description Cause Code Overcurrent, Blowout Fuse, Current Sensor Failure, Abnormality Running Current at Compressor instantaneous Power Failure, Voltage Drop, Abnormal Power Constant! Speed Compressor Supply Abnormality of Outdoor Unit Capacity Outdoor Unit Capacity >...