Operating Problems - INOXPA OVERFLOW VALVE Installation, Service And Maintenance Instructions

Table of Contents

Advertisement

7. Operating problems

Valve does not close
Internal leak of product (valve closed)
External leak of product
Valve does not open/close
Dirt and/or foreign body between the shaft sleeve
and the valve body seat.
The springs are not applying pressure on the
shaft stop washer.
The shaft sleeve seal is worn or defective
Normal wear of the seals
Premature 
wear of the
seals
Back pressure
Body seal defective
Shaft seal defective
Deformation of seat seal
Spring in poor condition and/or jam for the dirt
The valve does not open when the pressure
increases
INOXPA S.A.U.
10.207.30.07EN · (0) 2023/11
PROBABLE CAUSES
Sealing gasket worn or affected by 
the product
Excessive pressure in the line
Working temperature too high
Loss of tightness (vibrations)
SOLUTIONS
- Clean the body and the seat
- Increase the tightening torque of the springs
- Replace the seals
- Replace the seals
- Replace the seals with others of different mate-
rial and more adequate for the product
- Tighten the loosening pieces
- Clean frequently
- Change the spring with a stronger one
- Replace the seals with new ones
- Replace the seat seal with another of different 
quality if it has deteriorated prematurely
- Replace or clean the spring and the shaft
- Calibrated the valve
Operating problems
13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OVERFLOW VALVE and is the answer not in the manual?

This manual is also suitable for:

74700

Table of Contents