7. INSTALLATION:
STEPS 10 through 18:
10. NOTE: This unit contains the QUASAR UV-C LED.
IMPORTANT:
REVIEW Section 4: QUASAR UV-C LED OPERATION before proceeding. Failure to follow
Section 4 can damage the QUASAR. Do not attempt to operate the electronic bottle filler
dispenser until the cooling tank is filled and the water filters are flushed.
11.
Purging Air From Cooling Tank and Flushing Filters:
• Remove top of unit by removing one screw on each side of the top.
• Locate the ball valve as shown in Diagram 7
• Place a container in the alcove
• Open the ball valve and leave open until water comes out continuously without any air. If
filters are installed, continue to run water until the water runs clear. Then close the Ball
Valve.
12.
Check system for any leaks.
13.
Rotate the fan blade to see that it is free of obstructions.
14.
ENERGIZING UNIT: Check the available power supply against the water dispenser data plate to
ensure correct electrical service. This water dispenser is intended to be connected to a 20A
minimum ground fault circuit interrupting (GFCI) device to meet UL requirements. Plug Power
Supply Cord into outlet.
15.
Place bottle in alcove to purge additional air in Cooling Tank and water lines. The Water
Dispenser sensor will run for 20 seconds and shut-off. Do this 2 or 3 times until a steady
stream of water dispenses.
16.
SETTING UP PCB ELECTRONICS: Follow instructions in Section 8 to change default setting.
17.
Re-install Front Panel, and 2 screws.
18.
Set up is complete. Enjoy!