Technical specifications

1x230 V
Output data according to EN 14 511
1
Heating capacity (P
)/COP
H
2
Heating capacity (P
)/COP
H
3
Heating capacity (P
)/COP
H
Output data according to EN 14 825
Rated heating output (P
)
designh
SCOP cold climate, 35°C / 55 °C
SCOP average climate, 35 °C / 55 °C
SCOP warm climate, 35°C / 55°C
Additional power
Max power, immersion heater (factory setting)
Energy rating, average climate
The product's efficiency class room heating, average climate 35 / 55 °C
The system's efficiency class room heating, average climate 35 / 55 °C
Declared tap profile/efficiency class hot water heating
Electrical data
Rated voltage
Max operating current
Min. fuse rating
Drive output heating medium pump
Driving power exhaust air fan
Driving power supply air fan
Enclosure class
Equipment Compliant with IEC 61000-3-12
For Connection Design Purposes, Compliant with Class A limits of IEC 61000-3-2
For Connection Design Purposes, Compliant with IEC 61000-3-3 technical requirements
Refrigerant circuit
Type of refrigerant
Volume
Cut-out value pressostat HP
Cut-out value pressostat LP
Heating medium circuit
Opening pressure, safety valve
Operating pressure (supply line)
Max temperature, supply line (factory setting)
Ventilation
Min. air flow at exhaust air temperature at least 20°C
Min. air flow at exhaust air temperature below 20°C
Sound effect level according to EN 12 102
7
Sound power level (L
)
W(A)
Sound levels
Sound pressure level in the installation room (L
Pipe connections
Heating medium ext Ø
Hot water ext Ø
Cold water ext Ø
Docking ext Ø
Ventilation Ø
1
A20(12)W35, exhaust air flow 56 l/s (200 m
2
A20(12)W45, exhaust air flow 42 l/s (150 m
3
A20(12)W55, exhaust air flow 31 l/s (110 m
4
Scale for the product's efficiency class room heating: A+++ to D.
5
Scale for the system's efficiency class room heating: A+++ to G. Reported efficiency for the system takes the product's temperature
regulator into account.
6
Scale for efficiency class hot water: A+ to F.
7
The value varies with the selected fan curve. For more detailed sound data, including sound to channels, visit nibe.co.uk.
8
The value can vary with the room's damping capacity. These values apply at a damping of 4 dB.
NIBE F470
4
5
6
8
)
P(A)
3
/h)
3
/h)
3
/h)
Stainless
kW/-
2.18 / 3.93
kW/-
2.03 / 3.24
kW/-
1.88 / 2.74
kW
3
kW
3.70 / 3.08
kW
3.58 / 2.98
kW
3.58 / 2.98
kW
8.0 (5.3)
A+ / A+
A+ / A+
L / A
V
230 V ~ 50 Hz
A
41
A
10
W
4-34
W
25-140
W
25-140
IP 21
R290
kg
0.44
MPa/bar
2.45 / 24.5
MPa/bar
0.15 / 1.5
MPa/bar
0.25 / 2.5
MPa/bar
0.2 / 2.0
°C
70 (60)
l/s
28
l/s
31
dB(A)
51.5-54.5
dB(A)
47.5-50.5
mm
22
mm
22
mm
22
mm
22
mm
125
Chapter 12 | Technical data
63