Disturbances in comfort

In most cases, the heat pump notes operational interference
(operational interference can lead to disturbance in hot
water comfort) and indicates this with an alarm in the dis-
play.

Info menu

All the heat pump measurement values are gathered under
menu 3.1 in the heat pump menu system. Looking through
the values in this menu can often simplify finding the source
of the fault.

Manage alarm

alarm 291
charge pump
aid mode
reset alarm
no
In the event of an alarm, a malfunction has occurred, which
is indicated by an alarm symbol in the display.
ALARM
In the event of an alarm a malfunction has occurred that
F110 cannot rectify itself. The display shows what type of
alarm it is and lets you reset the alarm. You can also choose
to set the heat pump to rescue mode
reset alarm In many cases it is sufficient to select "reset
alarm" to correct the problem that caused the alarm. If the
alarm recurs, the problem that caused the alarm remains.
If the alarm initially disappears and then returns, you should
contact your installer.
aid mode "aid mode" is a type of emergency mode. This
means that the heat pump produces hot water despite there
being some kind of problem.
This can mean that the heat pump's compressor is not run-
ning. In this case the immersion heater produces hot water.
Caution
Selecting "aid mode" is not the same as correcting
the problem that caused the alarm. The alarm
symbol will remain displayed.
If the alarm does not reset, contact your installer for suitable
remedial action.
NIBE F110
yes
Caution
You need the product's serial number for servicing
and support.

Troubleshooting

If the operational interference is not shown in the display
the following tips can be used:
BASIC ACTIONS
Start by checking the following items:
Group and main fuses of the accommodation.
The property's earth circuit breaker.
Heat pump's earth-fault breaker.
LOW HOT WATER TEMPERATURE OR A LACK OF
HOT WATER
Large hot water consumption.
Wait until the hot water has heated up. Temporarily in-
creased hot water capacity (temporary lux) can be ac-
tivated in menu 2.1.
Too low hot water setting.
Enter menu 2.2 and select a higher comfort mode.
Filter clogged (installation with ambient air)
Clean or replace the filter.
Thermostat setting too low
Contact your installer!
Low or a lack of ventilation (exhaust air installation)
See section "Low or a lack of ventilation".
Applies to incoming air blocked (outdoor air installation)
Clean the grille.
LOW OR A LACK OF VENTILATION (EXHAUST
AIR INSTALLATION)
Filter blocked.
Clean or replace the filter.
The ventilation is not adjusted.
Order ventilation adjustment.
Exhaust air device blocked or throttled down too much.
Check and clean the exhaust air devices.
Fan speed in reduced mode.
Enter menu 1 and select "normal".
LOUD OR DISTURBING VENTILATION (EXHAUST
AIR INSTALLATION)
Filter blocked.
Chapter 4 | Disturbances in comfort