SPX Radiodetection SENSORS & SOFTWARE LMX150 Operation Manual page 103

Ground penetrating radar
Table of Contents

Advertisement

Troubleshooting
4) Check the LMX Sensor and Display Unit Connectors
Turn off the LMX system and disconnect the battery before disconnecting the cable that
connects the Display Unit to the LMX Sensor.
a) On the back of the Display Unit, check that none of the 37 pins are missing, bent, or
recessed. Look at the pins on an angle to confirm they are all flush with one another. If one
is bent or recessed, gently bend the pin back straight and flush with the other pins. Then
reconnect the cable and try powering the LMX system again.
b) Check all 37 sockets at the LMX connector, ensuring that none are blocked with debris.
If so, clean out the debris, reconnect the cable and try powering the system again.
103