Installation - universalblue UAA3000R32-19 Instruction Manual

Inverter air conditioner split a ++
Table of Contents

Advertisement

Available languages

Available languages

3. To turn the power off, press the emergency button again (you will hear a long
beep).
4. After 30 minutes of forced operation after using the emergency button, the unit
will automatically run at 23º in cold mode with fan in automatic speed.
TEMPERATURE SETTING
The air conditioning is programmed to be used based on the temperatures listed
below. If temperatures other than those listed above are used, certain protective
measures may be activated to prevent irreparable damage to the device.
TEMPERATURE
MODE
Room temp.
Outdoor temp.
The unit does not operate immediately if it is turned on after being turned off or
after changing the operating mode. This is a common form of self-protection
and you need to wait about 3 minutes to work again.
Information based on factory test performed *
* Max. motor speed of indoor unit and maximum opening angle of fins
5.

INSTALLATION

PRECAUTIONS:
• The appliance must be installed by authorized professional
personnel. Otherwise the appliance may be automatically
without any warranty from the manufacturer.
• The gas in the appliance may only be charged by authorized
professional personnel. This task is dangerous and can
cause damage if not performed properly.
• A test to check for possible gas leaks should be performed
once the equipment has been installed.
• The requirements regarding the type and quantity of gas in
each appliance can be found in this manual.
GAS CHARGE AND MINIMUM AREA
m3
M1 = (4
) x LFL , m2= (26
/
COOL MODE
17 Cº to 32 Cº
0 Cº to 53 Cº
-15 Cº to 53 Cº
some models only)
m3
)x LFL , m3= (130
HEAT MODE
0 Cº to 30 Cº
-15 Cº to 30 Cº
(For
m3
)x LFL
DRY MODE.
10 Cº to 32 Cº
0 Cº to 50 Cº
52