automatically increase by 1°C every 60 minutes, up to a maximum of 2°C.
In heat mode, the set temperature is gradually reduced by 2°C during the first 2 hours
of operation.
After 10 hours of operation in NIGHT mode, the air conditioning will automatically turn
off.
EMERGENCY FUNCTION AND RESTART OF THE APPLIANCE
Reset: In the event of a power failure, the
device memorizes the conditions of use
before the power failure and, once the device
is back in operation, it will start in the same
mode, temperature and speed as it was
previously in operation.
To desactivate the function, proceed as
follows:
1. Switch
off
disconnect it from the power supply.
2. Press the emergency button while
switching on the power.
3. Press the emergency button for 10
seconds until you hear a sound. The restart
function has been deactivated.
4. To activate the function again, repeat
this procedure until you hear the sound 3
times.
EMERGENCY: If the remote control fails,
open the front cover of the indoor unit
and look for the emergency button.
1. Press the emergency button once
(until you hear a sound) and the device
will be forced to work in COLD mode.
2. Press the emergency button 2
times for 3 seconds (until you hear 2
sounds) and the device will be forced to
work in HEAT mode.