SECTION 3
PA-44-180, SEMINOLE
EMERGENCY PROCEDURES
3.5b fuel Management - One Engine Inoperative
cruising - One Engine Inoperative
When using fuel from tank on the same side as the operating engine:
FUEL Selector (Operating Engine) ...................................................... ON
FUEL Selector (Inoperative Engine) ..................................................OFF
FUEL PUMPS .....................................................................................OFF
(except in case of engine driven pump
failure when electric fuel pump on
operating engine side must be used)
When using fuel from tank on the side opposite the operating engine:
FUEL Selector (Operating Engine) ............................................... XFEED
FUEL Selector (Inoperative Engine) ..................................................OFF
FUEL PUMPS .....................................................................................OFF
(except in case of engine driven pump
failure, electric fuel pump on operating
engine side must be used)
NOTE
Use XFEED in level cruise flight only.
Landing - One Engine Inoperative
FUEL Selector (Operating Engine) ...................................................... ON
FUEL Selector (Inoperative Engine) ..................................................OFF
ISSUED: June 5, 2013
REPORT: VB-2307
3-17