3.5l hydraulic Pump failures
hydraulic pump will not deactivate:
Indication: Master caution, Double chime,
GEAR PUMP Circuit Breaker (Row 2, Col. 12) ........ ................PULL
Prior to landing:
GEAR PUMP Circuit Breaker (Row 2, Col. 12) ........................PUSH
If GEAR PUMP Circuit Breaker Opens:
Complete Manual Extension of Landing Gear checklist
hydraulic pump will not activate:
Indication: Gear Position Indications remain in current position
GEAR ........................................................ RETURN to Original Position
GEAR PUMP Circuit Breaker (Row 2, Col. 12) .........................RESET
GEAR ..................................................................................... RESELECT
If landing gear remains up (prior to landing):
Complete Manual Extension of Landing Gear checklist
If landing gear remains down:
Airspeed ................................REMAIN BELOW V
REPORT: VB-2307