1. Product Specifications
1-1. Cylinder specification
Bore size (mm)
Action
Fluid
Proof pressure
Max. operating pressure
Min. operating pressure
Ambient and fluid
temperatures
Lubricant
Piston speed
Stroke length tolerance [mm]
Cushion
Port size
Mounting
* Load is limited depending on the piston speed at the time of locking, mounting direction and operating pressure.
** Use the product so that the kinetic energy does not exceed the allowable value of the cylinder.
(Refer to "Allowable kinetic energy of the cylinder "(Page 7)".)
W a r n i n g
・Confirm the specifications.
This product is designed only for use in compressed air systems including vacuum. Do not operate at pressures or
temperatures outside of the specification, as this could cause damage or malfunction (Refer to the specifications.)
Please contact SMC if using fluids other than compressed air (including vacuum) generated by air compressor.
SMC does not guarantee against any damage if the product is used outside of the specification range.
・Confirm the applicable specification range.
These product specifications apply to all standard strokes including intermediate strokes. Please contact SMC for
specifications for a long stroke.
1-2. Lock unit specifications
Bore size (mm)
Locking action
Max. operating pressure
Min. operating pressure
Locking direction
Holding force(Maximum static load)(N) *
* The holding force (max. static load) shows the maximum capability and does not show the normal holding capability.
Choose the cylinder based on the Selection graph (Page 5).
1-3. Stop accuracy
Bore size (mm)
Lock type
Stopping accuracy (mm)
Conditions
32
40
Without auto switch:-10℃ to 70℃
With auto switch:-10℃ to 60℃
+2.0
Up to 500st:
501 to 1,000st:
,
0
Air cushion on both ends + Bumper cushion
G1/8
Basic , Axial foot , Rod flange, Head flange,
Single clevis, Double clevis, Center trunnion
32
630
32
40
・Mounting orientation ・・・ Horizontal
・Supply pressure ・・・ 0.5MPa
・Piston speed ・・・ 300mm/s
・Load condition ・・・ Upper limit of allowed value
Solenoid valve for locking is mounted on the unlock port.
Maximum value of stopping position dispersion from 100 measurements
50
63
Double acting/single rod
Air
1.5MPa
1.0MPa
0.08MPa
Not required (Non-lube)
50 to 1,000mm/s *
+2.4
, 1,001 to 1,500st:
0
G1/4
40
50
Exhaust locking
1.0MPa
0.3MPa or more
Both directions
980
1570
50
63
Exhaust locking
±1.0
- 4 -
80
100
(No freezing)
+2.8
, 1,501 to 1900st:
0
G3/8
G1/2
63
80
2450
3920
80
100
+3.2
0
100
6080
Need help?
Do you have a question about the C96N C Series and is the answer not in the manual?
Questions and answers