Page 1
NAAMS Standards Compliant Power Clamp Cylinder ø50, ø63 RoHS A new structure has achieved downsizing. Overall length reduced by max. CKZ5N Bore size CKZ3N a Reduction 377 mm 392 mm 17.3 Depth reduced by max. Bore size CKZ3N a CKZ5N Reduction 128.7 136 mm...
Page 2
NAAMS Standards Compliant Power Clamp Cylinder CKZ5N Series ø50, ø63 How to Order CKZ5N R T F Base type Bore size Front mounting hole ø50 equivalent (No) (Yes) ø63 equivalent Cylinder port Front mounting hole Arm opening angle Proximity switch Arm opening TURCK Symbol...
Page 3
NAAMS Standards Compliant CKZ5N Series Power Clamp Cylinder Cylinder Specifications Bore size Action Double acting Fluid Proof pressure 0.9 MPa Max. operating pressure 0.6 MPa Min. operating pressure 0.3 MPa Ambient and fluid temperatures −10 to 60°C (No freezing) Clamping side: None Cushion Unclamping side: Rubber bumper Operating time...
CKZ5N Series Replacement Parts Switch kit Stopper bolt kit Switch Kit No. Stopper Bolt Kit No. CKZ5 S063 CKZ5 B063 Proximity switch Arm opening angle TURCK 15° P&F 30° None 45° ∗ The switch kit includes mounting brackets. 60° 75° 90°...
Page 5
NAAMS Standards Compliant CKZ5N Series Power Clamp Cylinder Dimensions (Dual arm) Clamp arm mounting shaft (Left arm) (Right arm) Release point (square shape) ±0.02 ±0.05 2 x 2 x ø depth 2 x 2 x depth 12 1/4 (G, NPT, Rc) Unclamping port 1/4 (G, NPT, Rc) Clamping port...
Page 6
CKZ5N Series Bore Size Clamp Arm Code List Dimensions: Clamp Arm Straight: Plain Bore size SMC part no. Clamp arm code NAAMS code Page CKZ-50A001 A001 ACA201M CKZ-50A002 A002 ACA202M CKZ-50A003 A003 ACA203M CKZ-50A004 A004 ACA206M CKZ-50A005 A005 ACA207M M6 x 1.0 CKZ-50A006 A006 ACA208M...
Page 7
NAAMS Standards Compliant CKZ5N Series Power Clamp Cylinder Bore Size Dimensions: Clamp Arm 20 mm offset: Plain 45 mm offset: Plain M6 x 1.0 M6 x 1.0 [mm] [mm] Model NAAMS code Weight [kg] Model NAAMS code Weight [kg] CKZ-50A007 ACA211M CKZ-50A013 ACA221M...
Page 8
CKZ5N Series Bore Size Dimensions: Clamp Arm Straight: Plain 20 mm offset: Plain M8 x 1.25 M8 x 1.25 [mm] [mm] Model NAAMS code Weight [kg] Model NAAMS code Weight [kg] CKZ-63A001 ACA001M CKZ-63A013 ACA013M 135.0 135.0 CKZ-63A002 ACA002M CKZ-63A014 ACA014M 165.0 165.0...
Page 9
NAAMS Standards Compliant CKZ5N Series Power Clamp Cylinder Bore Size Dimensions: Clamp Arm 65 mm offset: Plain 115 mm offset: Plain M8 x 1.25 M8 x 1.25 [mm] [mm] Model NAAMS code Weight [kg] Model NAAMS code Weight [kg] CKZ-63A025 ACA025M CKZ-63A037 ACA037M...
CKZ5N Series Model Selection Relation between arm length and clamping force Arm length Clamp arm Shim Clamping block Fulcrum Clamping position Bore Size: Bore Size: 8000 10000 0.6 MPa 0.6 MPa 8000 6000 0.5 MPa 0.5 MPa 6000 0.4 MPa 0.4 MPa 4000 4000...
CKZ5N Series Setup Procedure Precautions 1) The tightening torque of the clamp arm is 12 to 15 N·m for ø50 and 15 to 20 N·m for ø63. Refer to pages 5 to 8 for details on the clamp arm. 2) This product is designed to be used after being externally adjusted using a shim, and there is a mechanical difference of −0.25°...
Page 12
CKZ5N Series Power clamp cylinder mounting and setup procedure <Ex. 2 When using a hard stop: When not equipped with a workpiece receptacle> Clamp arm Shim q Upper hard stop Clamp arm Shim w Shim q Arm side block Unclamping port Upper hard stop Clamping port Hard stop (Section A)
Page 13
CKZ5N Series Setup Procedure Relation between shim thickness and clamping force ∗ Use this figure as a guide as there is a tolerance of about 10% in the clamp cylinder body. ∗ When a shim exceeding the peak clamping force position on the graph is inserted, the lock will not be activated when clamped. Insert a shim of the appropriate thickness.
Page 14
CKZ5N Series To change the arm opening angle Caution Be sure to confirm safety, and perform the work while the air is exhausted. z Procedure for changing the stopper bolt 1) Remove the stopper bolt of the head cover, and replace with a stopper bolt for the desired angle using the tightening torque below. When tightening the stopper bolt, hold the head cover.
CKZ5N Series Specific Product Precautions Be sure to read this before handling the products. Refer to the back cover for safety instructions. For actuator precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual” on the SMC website: https://www.smcworld.com Caution Caution 1.
These safety instructions are intended to prevent hazardous situations and/or Safety Instructions equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for ∗1) safety and must be followed in addition to International Standards (ISO/IEC) and other safety regulations.