7.2. Code Reader Setup

Set up the code reader.
Precautions for Correct Use
Use a PC (personal computer) to set the parameters for the code reader.
Note that you may need to change the PC settings depending on the condition of your PC.
7.2.1.
Setting the Parameters
Set the parameters for the code reader.
Set the IP address of your PC to 192.168.188.100 and its subnet mask to 255.255.0.0.
1
Connect the cord reader and the
switching hub to the PoE
injector with cables.
2
Connect the PC to the switching
hub with a LAN cable.
Connect 24 VDC power supply
(for the switching hub) to the
switching hub.
3
Set the IP Address of the PC.
For the IP address, enter
192.168.188.100. For the
subnet mask, enter 255.255.0.0.
For the procedure to open the
screen on the right, please refer
to the next step 4.
Switching hub
PoE hub
W4S1-05C
LAN cable
LAN cable
7. Connection Procedure
V460-H0PX
Ethernet
cable
24 VDC power supply
11