Omron V460-H Series Connection Manual page 25

Industrial handheld dpm reader
Hide thumbs Also See for V460-H Series:
Table of Contents

Advertisement

5
The Watch window Tab Page
is displayed under the Edit
Pane.
Confirm that the variables
6
shown in the figure on the right
are listed in the Name column.
* If any of the required
variables are not listed, click
Input Name and add them.
* In the following description,
"Program0" of the variable
names in the Name column is
omitted.
7
Click TRUE in the Modify
column of Input_Start.
The Online value of
Input_Start changes to True.
8
Press the trigger button on the code reader within 15 seconds after the online value
changes to True to read the code. This program will end with an error after a certain period
of time because the communication processing branches to the error end.
9
When the communications
have ended normally, the
values of the error codes are 0.
The value of the TCP
connection status
(Output_EtnTcpSta) is
_CLOSED.
* If the program ends with an
error, the error code will be
stored according to the error
that occurred. Refer to 9.6.
Error Processing for details
on error codes.
Program execution status
7. Connection Procedure
Start of input
Error codes
TCP
connection
status
Receive data Send data
22

Advertisement

Table of Contents
loading

Table of Contents