Code Reader Setup - Omron V330-F Series Quick Start Manual

Corporation auto focus multi code reader
Hide thumbs Also See for V330-F Series:
Table of Contents

Advertisement

7.2. Code Reader Setup

Set up the code reader.
Precautions for Correct Use
Use a PC (personal computer) to set the parameters for the code reader.
Note that you may need to change the PC settings depending on the condition of your PC.
7.2.1.
Setting the Parameters
Set the parameters for the code reader.
Set the IP address of your PC to 192.168.188.101 and its subnet mask to 255.255.0.0.
1
[Using V330-F]
Connect the cord reader and the
switching hub to the PoE
injector with a LAN cable.
[Using V430-F]
Connect the Ethernet connector
of the code reader to the
switching hub with the Ethernet
cable.
Connect the I/O cable to the I/O
connector and turn ON the 24
VDC power supply.
* In this document, only the
power supply wires of the I/O
cable are connected and
checked. Be careful not to
short-circuit any other wires.
* Ground the shield wire as
needed. For more information
on grounding, please refer to
Grounding in Appendices of
the MicroHAWK
V320-F/V330-F/V420-F/V430-
F Series Barcode Reader User
Manual (Cat. No. Z432).
Switching
hub
PoE injector
W4S1-05C
LAN cable
Ethernet cable
V430-WE-3M
I/O
Ethernet
Connector
Connector
I/O Cable
V430-W8-3M
7. Connection Procedure
V330-F064N12M
-NNX
LAN cable
Switching
hub
Red Striped
Gray Striped
24 VDC
power
supply
12