Static connection (Setting the fixed IP address)
4
(1) Click the Start Button at the lower left corner of the screen, and then click Settings.
(2) Select Windows Settings – Network & Internet.
(3) Under Change your network settings, click Change adapter options.
(4) In Network Connections, right-click on the Ethernet icon and select Properties.
(5) In the Ethernet Properties Dialog Box, select Internet Protocol Version 4 (TCP/IPv4),
and click the Properties Button. Set the IP Address of the PC to 192.168.188.100.
(6) Click the OK Button.
5
Start your browser and enter
http://192.168.188.2.
"Google Chrome" is the
recommended browser.
When the WebLink
6
HH
screen is displayed, go to step
8.
If you cannot access by
WebLink
, go to step 7.
HH
If the WebLink
startup screen does not appear, it means that communications are not
7
HH
established between the code reader and the PC. Please check the following.
• The code reader and the PC have a proper physical (cable) connection.
→ Refer to steps 1 and 2 for checking the connection.
• The IP Addresses of the PC and code reader are set correctly.
→ Refer to step 4 for setting the IP address of the PC.
For other measures that can be taken, please refer to When unable to access by WebLink
in 8-3 Q&A of the V460-H Industrial Handheld DPM Reader User Manual (Cat. No. Z461).
The WebLink
screen
8
HH
appears.
startup
7. Connection Procedure
HH
12