DC Circuit Protector (or DC Fuse)
The DC circuit protector(or DC Fuse) automatically shuts off the DC battery charging circuit when
the DC circuit is overloaded, when there is a problem with the battery, or the connections between
the battery and the generator are improper.
The indicator inside the DC circuit protector button will pop out to show that the DC circuit protector
has switched off. Wait a few minutes and push the button in to reset the DC circuit protector.
Connecting the battery cables:
1) Before connecting charging cables to a battery that is installed in a vehicle, disconnect the
vehicle's grounded battery cable.
WARNING
The battery gives off explosive gases; keep spark, flames and cigarettes away. Provide adequate
ventilation when charging or using batteries.
2) Connect the positive (+) battery cable to the battery positive (+) terminal.
3) Connect the other end of the positive (+) battery cable to the generator.
4) Connect the negative (-) battery cable to the battery negative (-) terminal.
5) Connect the other end of the negative (-) battery cable to the generator.
6) Start the generator.
NOTICE
Do not start the vehicle while the battery charging cables are connected and the generator
is running. The vehicle or the generator may be damaged.
An overloaded DC circuit will fuse the DC fuse, if this happens, replace fuse.
16