Energizer EZG6000 User Manual page 27

Table of Contents

Advertisement

Before storing the unit for an extended period:
• Be sure the storage area is free of excessive humidity and dust.
• Service according to the table below:
STORAGE TIME
Less than 1 month
1 to 2 months
2 months to 1 year
1 year or more
*Use gasoline conditioners that are formulated to extend storage life.
Contact your authorized generator dealer for conditioner recommendations.
1) Drain the carburetor by loosening the drain screw. Drain the gasoline into a suitable container.
WARNING
Gasoline is extremely flammable and is explosive under certain conditions. Perform this
task in a well ventilated area with the engine stopped. Do not smoke or allow flames or
sparks in the area during this procedure.
The fuel of this machine is combustible and deflagrating. After the machine has been shut down,
the additional fuel must be treated properly and the local environmental requirements must be met.
2) Change the engine oil
3) Remove the spark plug, and pour about a tablespoon of clean engine oil into the cylinder. Crank
the engine several revolutions to distribute the oil, then reinstall the spark plug.
RECOMMENDED SERVICE PROCEDURE TO PREVENT HARD STARTING
No preparation required.
Fill with fresh gasoline and add gasoline conditioner*
Fill with fresh gasoline and add gasoline conditioner*
Drain the carburetor float bowl.
Drain the fuel sediment cup.
Fill with fresh gasoline and add gasoline conditioner*
Drain the carburetor float bowl.
Drain the fuel sediment cup.
Remove the spark plug. Put a tablespoon of engine oil into the cylinder. Turn the
engine slowly with the pull rope to distribute the oil.
Reinstall the spark plug.
Change the engine oil.
After removal from storage, drain the stored gasoline into a suitable container, and
fill with fresh gasoline before starting.
27