Safety Instructions

Read this manual for instructions on the proper use and safety information for the product. The safety instructions provided herein are for illustrative purposes that include but are not limited to those listed in this manual. Actual operation shall comply with all applicable safety standards. If you have any questions, feel free to contact BLUETTI support or your local BLUETTI dealers.

  1. Charge the unit before first use.
  2. Do not use solar panels with open circuit voltage higher than 58V. Solar input voltage range for the unit is 12V-58VDC.
  3. Charge the unit immediately when the SoC drops below 5%. If the SoC drops to 0, power off the unit and charge it for at least 30 minutes before restarting.
  4. The unit is for off-grid use only. Do not connect its AC output to the grid.
  5. If not used for more than 3 months, charge the unit to 40%-60% SoC and store it with the power off. For optimum battery life, discharge and charge the unit every 3 months.

Statement

To ensure a safe operation, it's crucial to observe and adhere to the following conditions:

  • Always operate or store the product in the conditions specified in this manual.
  • Avoid unauthorized disassembly, component replacement, or modification of software codes.

caution BLUETTI shall not be liable for damages resulting from the following circumstances:

  • Force majeure events such as earthquakes, fires, storms, floods, or mudslides.
  • Damage caused by the customer's own transportation.
  • Damage resulting from inadequate storage conditions as specified in the manual.
  • Damage caused by customer negligence, improper operation, or intentional actions.
  • System or hardware damage caused by third parties or customers, including but not limited to improper handling and installation not in accordance with the instructions in this manual.
  • Usage of the product with devices that require a high-performance Uninterruptible Power Supply (UPS), including but not limited to data servers, workstations, medical equipment, and other similar devices.

General Requirements

INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS IMPORTANT SAFETY INSTRUCTIONS

When using this product, basic precautions should always be followed, including the following:

  1. Read all the instructions before using the product.
  2. To reduce the risk of injury, close supervision is necessary when the product is used near children.
  3. Do not put fingers or hands into the product. And do not insert foreign objects into any ports of the product.
  4. Use of an attachment not recommended or sold by the manufacturer may result in a risk of fire, electric shock, or injury to persons.
  5. To reduce the risk of damage to the electric plug and cord, pull the plug rather than the cord when disconnecting the product.
  6. Do not use a battery pack or appliance that is damaged or modified, as they may exhibit unpredictable behavior resulting in fire, explosion, or personal injury.
  7. Do not operate the product with a damaged cord or plug, or a damaged output cable.
  8. DO NOT attempt to replace the internal battery or any other component of the product by anyone other than authorized personnel. There are no end-user serviceable components. Do not disassemble the product, take it to a qualified service person when service or repair is required. Incorrect reassembly may result in a risk of fire or electric shock.
  9. To reduce the risk of electric shock, unplug the product from the outlet before attempting any instructed servicing.

  10. RISK OF EXPLOSIVE GASES. To reduce the risk of battery explosion, follow these instructions and those published by the battery manufacturer and manufacturer of any equipment you intend to use in the vicinity of the battery. Review cautionary markings on these products and engines.
  11. PERSONAL PRECAUTIONS
    1. Wear complete eye protection and clothing protection. Avoid touching eyes while working near the battery.
    2. NEVER smoke or allow a spark or flame in the vicinity of the battery or engine.
    3. Be extra cautious to reduce the risk of dropping a metal tool onto the battery. It might spark or short-circuit the battery or other electrical parts which may cause an explosion.
  12. When charging the internal battery, work in a well ventilated area and do not restrict ventilation in any way.
  13. Under abusive conditions, liquid may be ejected from the battery; avoid contact. If contact accidentally occurs, flush with water. If liquid contacts eyes, additionally seek medical help. Liquid ejected from the battery may cause irritation or burns.
  14. Do not expose the product to fire or excessive temperature. Exposure to fire or temperature above 130°C may cause an explosion.
  15. Have servicing performed by a qualified repair person using only identical replacement parts. This will ensure that safety is maintained.
  16. DO NOT operate in wet conditions. If the product becomes wet, please thoroughly dry it before using.
  17. Please ensure proper ventilation while in use and do not obstruct fan openings. Inadequate ventilation may cause permanent damage to the product.
  18. DO NOT stack anything on top of the product while in storage or use. DO NOT move the product while operating as vibrations and sudden impacts may lead to poor connections to the hardware inside.
  19. In case of fire, use only a dry powder fire extinguisher appropriate for the product.

  20. RISK OF ELECTRIC SHOCK. Never use the product to supply power tools to cut or access live parts or live wirings, or materials that may contain live parts or live wirings inside, such as building walls, etc.
  21. To avoid contact with any liquids, do not use this product in the rain or high humidity.

Grounding Instructions

This product must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock.
This product is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided with the product - if it does not fit the outlet, have a proper outlet installed by a qualified electrician.

Storage Instructions

  1. When the SoC drops to 5%, please charge the product immediately.
  2. Before storing the product, charge it to 40% to 60% SoC to keep it in optimal condition. In addition, power off the unit and disconnect all electrical connections from it.
  3. Store the product in a cool and dry place, keeping it away from flammable or combustible materials and gases.
  4. The product can be safely stored within a temperature range of -20℃ to 40℃ (-4℉ to 104℉). However, if the storage duration exceeds one month, it's recommended to maintain an ideal storage temperature of around 30 (86℉).
  5. Fully cycle the product every 3 months to maintain the battery's health. It's NOT recommended to store the unit for extended periods of time, as it may affect its performance and overall lifespan.

If the SoC drops to 0 (during storage or upon startup), take the following actions to safely restart the product:

  • Shut down immediately.
  • Charge within 48 hours.
  • Keep it at an ambient temperature of 5℃ to 35℃ (41℉ to 95℉) for 24 hours before charging. It's recommended to charge the product via an AC source. If charging via solar energy, ensure that your solar system provides an output of more than 100W.

caution BLUETTI shall not be liable for any equipment damage caused by the violation of the above instructions.

cautioninformation The symbol displayed is intended to remind you to read the instructions in the literature accompanying the product before operation and maintenance.

  • Connect the product to a socket-outlet that has an earthing connection using the power cord provided.
  • The socket-outlet should be installed near the product and easily accessible for safety purposes.
  • NEVER dispose of a battery by throwing it into fire or a hot oven, or by mechanically crushing or cutting it, as these may cause it to explode.
  • Avoid leaving batteries in extremely high-temperature environments, as this can result in an explosion or the leakage of flammable liquid or gas.
  • The battery subjected to extremely low air pressure may result in an explosion or the leakage of flammable liquid or gas.
  • Attention should be drawn to the environmental aspects of battery disposal.
  • Please refer to the information on the exterior bottom enclosure for electrical and safety information before installing or operating the apparatus.

Packing List

Standard Packaging

Item Picture Qty.
Portable Power Station 1
AC Charging Cable 1
Car Charging Cable 1
Solar Charging Cable 1
Grounding Screw M5×10 1
User Manual 1

Optional Accessories
(Available on official BLUETTI website)

Item Picture
USB-C to USB-C Cable (Output)
Cigarette Lighter to DC5521 Cable (For 12V devices with DC5521 port, such as routers, cameras, etc.)
Lead-acid Battery Charger (Charge a 12V/10A lead-acid battery via AC70. For gasoline vehicle batteries only.)
Lead-acid Battery Charging Cable Kit (Charge the AC70 via a lead-acid battery.)
Battery Connection Cable Kit (Charge the AC70 via an expansion battery in Power Bank mode.)

Product Overview

Meet the AC70 portable power station - the ultimate companion for your travel and adventure needs. With a 1000W pure sine wave inverter and 768Wh LiFePO4 battery, it offers ample power for all your outing gadgets like phones, laptops, car refrigerators, and air conditioners. When you require even more power, it boasts the innovative Power Lifting mode to tackle higher resistive demands of up to 2000W, perfect for hairdryers, kettles, and other heating appliances. Thanks to Turbo Charging technology, you can enjoy the convenience of an 80% charge in just 45 minutes, and a full charge in 1.5 hours.
Whether you're embarking on outdoor adventures, road trips, or camping trips with friends, the AC70 is built to accompany you every step of the way. So, go ahead and embrace your travel plans with confidence, knowing that the AC70 will provide reliable power whenever you need it.
Product Overview

  1. DC Input
  2. DC Power Button
  3. LCD Screen
  4. Power Button
  5. AC Power Button
  6. AC Output
  7. Grounding Pole
  8. AC Input
  9. USB-A Port
  10. USB-C Port
  11. Cigarette Lighter Port

Power ON/OFF

Power ON/OFF

  • Power ON: Press and hold the for about 2 seconds to turn AC70 on.
    When the AC70 is on, press the again to turn on / off the LCD screen.
  • Power OFF: Press and hold the for 2 seconds to turn off the unit.
  • AC ON / OFF: When the AC70 is on, press the AC power button to turn it on / off.
  • DC ON / OFF: When the AC70 is on, press the DC power button to turn it on / off.

LCD Screen

LCD Screen Overview

  1. ECO Mode
  2. Turbo Charging
  3. Battery Capacity (SoC)
  4. Silent Charging
  5. DC Input
  6. Bluetooth Connection
  7. Fan
  8. AC Input Power
  9. AC Output Power
  10. Grid Connection
  11. DC Output
  12. AC Output
  13. Power Lifting Mode
  14. Charge / Discharge Remaining Time
  15. Charge / Discharge Status
  16. Low Temperature Alert
  17. High Temperature Alert
  18. Overload Alert
  19. Overcurrent Alert
  20. Fault Alert
  21. DC Output Power
  22. Low Voltage Alert
  23. DC Input Power

LCD Instructions

Startup LCD lights up
Shutdown LCD lights off
ECO Mode enabled
displays
Turbo Charging enabled
displays
State of Charge
Silent Charging enabled
displays
DC input
displays
Bluetooth connected
displays
Fan on or abnormal
displays or flashes
AC input power
AC output power
AC input
displays
DC output enabled
displays
AC output enabled
displays
Power Lifting Mode enabled
displays
Remaining charge / discharge time (hour)
displays
Charging or discharging
displays
Abnormal temperature
displays
Connected device(s) overheating
displays
Overload
displays
Overcurrent
displays
Error code report
displays
DC output power
Battery low (below 5%)
displays
DC input power
displays

Charging

AC70 supports four charging methods: AC, solar, car, and generator.

AC Charging

Plug the AC70 into a standard wall outlet and start charging. Once it's fully charged, the AC70 automatically stops charging to prevent overcharging. For a fast charge, you can enable Turbo Charging in the BLUETTI App, which allows for an 80% capacity in just 45 minutes at an ambient temperature of 25℃ (77 ℉).
AC Charging

Solar Charging

Connect the solar panels (in series or parallel) to AC70 via the solar charging cable. When receiving a continuous input of 500W, the AC70 will automatically stop charging within 2 hours. However, please be aware that the charging time may vary based on weather conditions, sunlight intensity, panel orientation, and other variables.
Solar Charging
Note: Make sure your solar panels meet the following requirements:
Voc: 12V-58V
Current: 10A Max.
Power: 500W Max.

Car Charging

Connect the AC70 to the vehicle's 12V / 24V cigarette lighter port via the car charging cable. The AC70 also automatically stops charging when it's fully charged. On average, it takes about 7-9 hours to refill the AC70 using a 12V port and 4-5 hours with a 24V port at an ambient temperature of 25℃ (77 ℉).
Car Charging
Note: Make sure your vehicle meets the following conditions for charging:

  • The vehicle is capable of supplying power.
  • The vehicle's engine is running during the charging process.

Generator Charging

Connect the AC70 to a generator via the AC charging cable. Under optimal conditions, it takes approximately 2 hours to reach a full charge at an ambient temperature of 25℃ (77 ℉).
Generator Charging
Note: Make sure your generator meets the following conditions for charging:

  • The generator boasts a stable power output that exceeds the charging requirement of the AC70.
  • The generator delivers a pure sine wave AC output with voltage and frequency that meet AC70's specifications.

caution For stable and efficient charging, avoid using unreliable power sources like wind turbines. Also, it's not recommended to run your devices with AC70 while it's charging with a generator.

Discharging

AC Discharging

Item Specifications Compatible Loads
2 × AC Outlet 120V
50Hz / 60Hz
Appliances up to 1000W power.
e.g., air conditioners, refrigerators

Note: Do not apply AC70 to loads higher than 1000W, as this may cause damage to AC70 and your devices.

DC Discharging

Item Specifications Compatible Loads
Cigarette Lighter Port 12V / 10A 12V DC appliances up to 120W power.
e.g., car refrigerator, air conditioner
2 × USB-A Port 5V / 2.4A Mobile phones and other small loads.
2 × USB-C Port 5 / 9 / 12 / 15 / 20V, 3A; 20V, 5A Mobile phones, laptops, etc.

Note: To ensure optimal performance, avoid short-circuiting the ports and keep them dry during use or storage. Additionally, do not block or cover the ports while ensuring proper ventilation.

Settings

The AC70 offers the convenience of adjusting its settings either via physical buttons or BLUETTI App. With the buttons located on the device itself, you have direct control over various settings such as ECO Mode, output frequency, charging modes, and other functionalities. Additionally, by using the BLUETTI App, you can access a user-friendly interface on your phone to conveniently monitor and control the AC70.

Setting Mode

When the screen is on and the AC output is off, press and hold the AC and DC power buttons for about 2 seconds till the frequency indicator flashes to enter Setting Mode.
Press and hold the AC and DC power buttons at the same time to exit Setting Mode.
Note: If you do not perform any operation in 1 minute, the AC70 will automatically exit Setting Mode and no changes will be saved.

ECO Mode

ECO Mode is a power-saving mode that is enabled by default. When operating on ECO Mode, the AC / DC output will automatically turn off if the AC70 is bearing low (less than 40W or the set power) or no load for a while.
Note: When connecting a small power device, disable the ECO Mode for a successful and uninterrupted charge experience.
In the Setting Mode, press the DC power button to enable or disable the ECO Mode. You'll see the icon displayed on the screen when it's enabled.

Frequency Switching

The current output frequency (50Hz / 60Hz) is displayed in the lower right corner of the screen. In the Setting Mode, press the AC power button to switch the frequency options based on your requirements.

Power Lifting Mode

Power Lifting Mode allows AC70 to handle high-power resistive loads up to 2000W, which is disabled by default. In the Setting Mode, press and hold the AC power button to enable or disable it. You'll see the icon displays on the screen when it's enabled.
This mode is particularly useful when using the AC70 with demanding heating devices such as kettles, electric blankets, and hairdryers. If the screen reads "OVERLOAD" while operating such devices, activating Power Lifting mode allows the AC70 to tackle these tasks effectively.
Note: The resistive loads should have a power rating between 1000W and 2000W. Although the AC70 can handle higher power demands, its actual operating power remains at 1000W.

AC Charging Mode

The AC70 supports 3 AC charging modes - Standard, Turbo, and Silent to fit your specific needs. In the Setting Mode, press the button to switch the options. Please refer to the below table for useful instructions.

AC Charging Mode Instructions

Mode Recharging Time Note
Standard 2 hours More friendly to AC70's battery.
Turbo 80% charge in 45 minutes; full charge in 1.5 hours Comes in handy when recharging time is a priority.
Silent 4 hours Offers a quiet, low-power operation for long battery life.

BLUETTI App

Scan the QR code below or search "BLUETTI" in the App Store or Google Play to download the BLUETTI App.

www.apple.com
play.google.com

For more details, please refer to BLUETTI APP INSTRUCTIONS.

Specifications

Model AC70
Country / Region JP US CN EU / UK / AU
Battery Capacity 768Wh / 24Ah
Cell Type LiFePO4
AC + DC Input 1000W Max.
Net Weight 10.2kg / 22.5lbs
Dimensions (L*W*H) 314mm × 209.5mm × 255.8mm / 12.4in × 8.2in × 10.1in
Charging Temperature 0°C-40°C / 32°F-104°F
Discharging Temperature -20°C-40°C / -4°F-104°F
Storage Temperature -20°C-40°C /-4°F-104°F
Working Humidity 10%-90%
AC Output
Power 1000W in total
Voltage 100VAC 120VAC 220VAC 230VAC
Current 10A 8.3A 4.5A 4.3A
Frequency 50Hz / 60Hz
DC Output
Cigarette Lighter Port 12VDC / 10A
USB-A *2 5VDC / 2.4A
USB-C *2 5 / 9 / 12 / 15 / 20VDC, 3A; 20VDC, 5A
AC Input
Voltage 100VAC 120VAC 220VAC 230VAC
Max. Current 9A 9A 6A 6A
Frequency 50Hz / 60Hz
UPS Switching time ≤20ms
Power 850W Max. (0%-80% in 45 minutes @ 10℃-40℃ / 50°F-104°F)
DC Input
Interface XT60PM-M
Power 500W Max.
Current 10A Max.
Voltage 12V-58VDC
Bluetooth 5.0 / 5.1
Max. Transmission Frequency 125kbps
Max. RF Transmission Power +12dBm
Receiver Sensitivity -99dBm / 1Mbps

Troubleshooting

In the Setting Mode, press and hold the DC power button until an error code appears on the screen. Please refer to the table below for helpful guidance.

Error Code Error Description Troubleshooting
E001 Inverter overload Check if the power consumption of your devices is too high. Reduce the load if necessary.
E002 Temperature protection Check if any of your devices are overheating. Allow them to cool down before use.
E003 Inverter short circuit Check if any of your electrical devices are causing a short circuit. Disconnect and resolve the issue.
E004 Output failure The output voltage is abnormal. Inspect the machine for any malfunctions or irregularities.
E016 Fan failure Check if the fan is blocked, unplugged, or not functioning properly. Ensure proper ventilation.
E033 PV overvoltage Make sure the PV input voltage is within the range of 12V-58VDC.
E065 Cigarette lighter output short circuit Check if the power consumption of your devices is too high. Reduce the load if necessary.
E068 Cigarette lighter output overtemperature Wait for the device connected to the cigarette lighter port to cool down.
E085 Charging temperature too high Wait for the unit to cool down before charging.
E086 Charging temperature too low Make sure the unit is placed in an ambient temperature of 0℃-40℃ (32°F-104°F).
E087 Discharging temperature too high Wait for the unit to cool down before discharging.
E088 Discharging temperature too low Make sure the unit is placed in an ambient temperature of 0℃-40℃ (32°F-104°F).
E113 Grid overvoltage Check if the grid voltage is too high. Contact your local power provider if necessary.
E114 Grid undervoltage Check if the grid voltage is too low. Contact your local power provider if necessary.
E115 Grid overfrequency Check if the grid frequency is too high. Contact your local power provider if necessary.
E116 Grid underfrequency Check if the grid frequency is too low. Contact your local power provider if necessary.
E117 Grid oscillation Disconnect the grid input and contact BLUETTI support for further assistance.
Others / Please contact BLUETTI support for assistance.

Estimating Operation Time

To estimate the operation time of the AC70, consider the load you're applying:

  • For high-power loads (above 300W):
    Operation time = Battery Capacity (Wh) x DoD x η ÷ Load Power
  • For small-power loads (below 300W):
    Operation time = Battery Capacity (Wh) x DoD x η ÷ (Load Power + Self-consumption of AC70)

Note: DoD refers to depth of discharge. AC70 works at 90% DoD for longer battery life. η is the conversion efficiency of the inverter, typically over 85% for AC70. The self-consumption of AC70 is approximately 15W.
E.g. If you have a 40W refrigerator, you can run it for about 10.7 hours. Operation time = 768Wh × 90% × 85% ÷ (40W + 15W) ≈ 10.7 hours.
Please keep in mind that the estimated operation time provided is for only purposes and may vary based on actual usage conditions. Factors such as low temperature and excessive loads can significantly affect the battery capacity, leading to a reduction in the average operation time.

FAQs

Q1: How do I know whether my devices will work well with this product?
A: Please evaluate the total constant load of your devices. If it doesn't exceed the Max. output power of AC70 (1000W), you can use this power station to run your devices.
Note: Some devices with built-in motor or compressor may start at 2-4 times the rated power, which can easily overload the AC70.

Q2: Can I use third-party solar panels to charge this product?
A: Yes, you can. However, make sure your solar panels have an open circuit voltage of 12V-58V and are equipped with MC4 connectors. It's also important not to mix different types of solar panels.

Q3: Can it charge and discharge at the same time?
A: Yes. It supports pass-through charging. The AC70 comes with the premium LiFePO4 battery and proprietary Battery Management System to ensure that it can charge and discharge at the same time.

Q4: What is ECO Mode and can I turn it off?
A: ECO Mode helps save power, and you can turn it on or off on the screen. When operating on ECO Mode, the AC / DC output will automatically turn off if the AC70 is bearing low or no load for a while. You can set the power threshold of AC output and DC output to 10W-30W / 5W-10W, respectively, for 1, 2, 3, or 4 hours.

Q5: Why is the charging power often too low?
A: AC70 has a built-in intelligent BMS that automatically adjusts the charging power in response to the battery temperature and SoC, thus protecting the battery and extending its service life.

For more information, please visit:
Web: https://www.bluettipower.com


@ BLUETTI Support
@ BLUETTI Official


@ bluetti_inc


@bluetti.inc


@bluetti_official


service@bluettipower.com

SHENZHEN POWEROAK NEWENER CO., LTD.
Add: F19, BLD No.1, Kaidaer, Tongsha Rd No.168, Xili Street, Nanshan, Shenzhen, China

USA Agent
Company: BLUETTI POWEROAK INC
Add: 6185 S VALLEY VIEW BLVD STE D LAS VEGAS NEVADA 89118 United States
FRN: 0033559824

Customer Service
Tel: 800-200-2980 (Monday to Sunday 9:00-17:00)
Email: sale@bluettipower.com (Pre-sales), service@bluettipower.com (After-sales)

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Bluetti AC70 - Portable Power Station Manual

Advertisement

Need Assistance?

Do you have a question about the AC70 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents