The appliance is supplied with a built-in operating unit.
Frame with
door (white)
Figure 21: Operating unit
Remove the decorative edging and door of the operating unit.
Fit the separate operating unit, where the gas regulator block and receiver will be
placed, on MAXIMUM 20" (50 cm) from either side of the appliance.
The burner, gas regulator block and receiver have been fully factory assembled.
Disconnect the bracket with the gas regulator block and receiver from the appliance.
Carefully move the bracket with the gas regulator block, receiver, pipes and cables to
the operating unit. Mount the bracket at the bottom of the operating unit.
Take care that no pipes get damaged and no compression fi ttings come
loose when moving the gas regulator block. Prevent twisting the fl exible
pipes! Check all compression fi ttings for leaks afterwards!
Mount the receiver in the top of the operating unit. Check afterwards that all electric
connections are properly connected.
Route all piping and cables from the operating unit to the appliance through an easily
accessible hollow cavity. During subsequent installation of the operating unit, protect
the gas regulator block and piping against encasement by cement etc.
Note: When the installation of the built-in operating unit is not possible; one can place
the gas regulator block and receiver under the appliance.
Important:
• Keep a minimal distance of 4" (10 cm) between the gas regulator block /
receiver and the bottom of the appliance.
• Attach the gas regulator block fi xed to the wall/fl oor.
• Gas regulator block and receiver must always be accessible for maintenance.