No. Wood chip
707
2.7

Overview of the control elements

2.7.1

Overview of the rear of the gas regulator block

A
B
C
D
E
F
G
H
Smart Bell 80-60
A
B
C
D
Item
Inlet pressure tap
Outlet pressure tap
Gas supply connection
Gas connection for the front burner
Adjustment screw for the minimum burner
pressure
Gas connection for the gas valve that is con-
nected to the rear burner
Thermocouple interrupter connection
Pilot light connection
No. Wood chip
E
F
Description
Point to measure the gas supply pressure
Point to measure the front burner pressure
The connection for the gas supply pipe
The connection for the front burner gas pipe
sets the minimum burner pressure. The ad-
justment screw is factory set and sealed.
The connection for the rear burner gas pipe
The connection for the thermocouple inter-
rupter
The connection to the pilot light gas pipe
Description
G
H