WARNING:
installation. Failure to follow instructions exactly can create a fi re hazard.
UNIT MUST SIT ON NON COMBUSTABLE SURFACE
The appliance must be installed on a non-combustible fl oor. If installed on, for
example, carpet or vinyl fl ooring, the appliance shall be placed on a plate of non-
combustible material extending the full width and depth of the appliance.
All clearances to combustible and non-combustible materials must be maintained as
described in this manual.
Clearances are in accordance with local installation codes and the requirements of the
gas supplier.
Never use combustible materials during the installation.
During installation of the appliance, a clearance of ⅛" (3 mm) should be maintained on
all sides of the appliance to allow for expansion of the appliance during operation.
Do not insulate the appliance! Only the top and sides may be fi tted with a strip of white,
loose insulation wool (heat-resistant to 1832°F (1000°C)), width 6" (15 cm) max. to
protect the wall.
Do not use fi breglass or Rockwool, or any other sort of insulating material. These emit
a pungent odour. This is considered extremely unpleasant. They may also cause
discolouring of the column.
Combustible materials, such as curtains, should not be placed in the vicinity of the
appliance. Minimum safe distance: 40" (100 cm).
Never place the appliance directly to a combustible or non-combustible rear wall and
side wall.
Bellfi res

CLEARANCES

Follow these instructions carefully to ensure safe
12
Installation instructions