3. INSTALLATION INFORMATION

Installation requirements:
A dedicated and properly earthed outlet. Unit should be protected by residual current
device (RCD) having a rated residual operating current not exceeding 30 mA.
The machine needs to be mounted on a firm level surface so there is no chance of it
toppling or falling over. A 100 mm air gap is required the whole way around the machine
to allow for sufficient ventilation.
The machine must not be installed in direct sunlight or next to a heat source. The supply
water must be potable and up to a maximum recommended temperature of 25°C (77°F).
Materials needed:
• PPE: rubber or nitrile safety gloves, safety footwear and protective eyewear
• Phillips screwdriver, temperature gauge, TDS meter and chlorine test strips
• Jug to collect water from the faucet and 10 litre container to drain the machine
• Aqua Dosa sanitise – or other 3% hydrogen peroxide
5/16" plastic tubing and assorted 5/16" quick connect fittings
• Sanitizing cartridge or Waterlogic filter housing without media.
• Install kit with non-return valve, pressure reducer and water block.
AUSTRALIAN INSTALLATION GUIDE
Installation in accordance with AS/NZS 3500.1 and AS/NZS 3500.2.
Waterlogic units must be installed according to the local guidelines. Waterlogic
units should only be connected to a potable drinking water supply. Waterlogic
units should not be connected to water supplies of unknown bacterial quality or
those not already fit for human consumption.
Waterlogic International strongly recommends the use of an anti-flood device.
Installation Instructions and parts required
1. K001 Install kit as below, (1 x 63058/103988 – brass tee, 1 x 54011/104115
ball valve, 1 x 52028/104177 dual check valve)
2. Serialised Unit
3. Diamond Flow Filter and Head
13