Culligan waterlogic BAR CLASSE Series Technical Manual page 14

Table of Contents

Advertisement

Options to above PLV
RMC PVDC50 dual check valve – 350 kpa PLV code 52010 / 100665
Accessories
1. JG ¼ sf x 3/8 stem elbow x 2 (for filter head) 60157 / 100963
2. JG ¼ sf x ¾ npt tap adaptor 60175 / 104065
3. Waterblock 50000 / 101084
4. JG ¼ sf x ¼ sf isolating valve 60127 / 100932
5. JG ¼ tube (black only) x 5 meters 60800 / 104105 roll
6. JG ¼ locking clips x 5 60124 / 104162
Any installation that requires us to run water ≥ 5M to our unit, must be using
AUSPEX or a Watermark equivalent product for all tubing runs. For our
compliance the product we use to run the water from the source to our unit
must be Watermarked.
After hours sales/service – 1300 88 14 14
START-UP INFORMATION
Only competent trained technicians should work on Waterlogic products. Waterlogic units may
weigh over 25 kg. We recommend caution when lifting. Packing materials could present a trip
hazard. Keep them off the floor.
• It is advisable to have the power and flexible water supply within a two meters range of
the machine. If water supply is further than two meters, rigid fixed permanent pipework
is required. All water connections shall be that of a fixed permanent solution and not by
temporary means of fixture:
0 - 2 meters: ≥ 5/16" JG pipe
2 - 10 meters: ≥ 15 mm pipe
• The isolation for the water and electricity should be easily accessible, and the machine
should not be installed using an extension lead.
• The water outlet connection must be fitted with an install kit containing a non-return valve,
a pressure reducer (maximum 3 bar) and a water block device. Prepare the connection to
the machine from the install kit via a length of 5/16" John Guest food grade tubing.
• Prepare the filter by carrying out a filter flush, making sure 10 litres of water pass
through the filter to clear any carbon fines that may need to be removed.
• Before turning ON the machine, take a sample of water from the supply and check
the TDS levels. If the TDS is less than to 30ppm you need to add 2.5 grams of
sodium bicarbonate to the Ice Bath to ensure it works efficiently.
The Ice Bath water is not used for consumption, so the addition of the sodium bicarbonate has no
effect on the quality of the drinking water.
A pressure higher than 3.5 bar will damage the machine, a pressure reducing valve is
necessary.