Operation; Filter Clog Indicator - Pressure Gauge - Baileigh Industrial DDTM-8052-HD Operator's Manual

Down draft table - metal
Table of Contents

Advertisement

OPERATION

CAUTION:
Always wear proper eye protection with side shields, safety
footwear, and leather gloves to protect from burrs and sharp edges.
The Welding Down draft table is designed for the filtration of smoke generated during ordinary
welding process work.
When installed and operated correctly, the machine will effectively collect and screen the smoke
yielding a significant improvement in air quality within the working environment.
• Press the Green On button to start and run the down draft table.
• Press the Red Off button to stop the down draft table.
Filter Clog Indicator – Pressure Gauge
When the machine is in operation, the pressure gauge
indicator should be between 2" ~ 4". This is normal.
If a decrease in vacuum is noted during operation
and/or pressure exceeds 6"; this means that the filters
are dirty and need to be cleaned or replaced.
• Power down the machine, remove the metal filter,
clean with water and then re-install.
If vacuum continues to be too weak for proper fume
extraction, after cleaning the metal filter, a new filter
will be required.
Note: The pressure is measured in
Inches of Water.