How To Set-Up The Gb731Shv5-Lb68 - Gage Bilt GB731SHV5/LB68 Original Instructions Manual

Installation tool
Table of Contents

Advertisement

WARNING:
Only qualified and trained operators shall install, adjust or use the assembly power tool for non-threaded
mechanical fasteners.
WARNING:
Operator
WARNING:
It is required that eye protection, hearing protection and safety boots be worn at all times while handling this
equipment.
WARNING:
The users or the user's employer must assess specific risks that could be present as a result after each use
based on their application.
Ensure there is adequate clearance for tool and operator's hands before proceeding. Keep fingers clear of any
moving parts. Keep fingers clear from fasteners and installed materials. Severe personal injury may result.
● Verify
Ensure that there are no electrical cables, gas pipes, etc., which can cause a hazard if damaged by the tool.
WARNING:
Do not actuate fastener in the air. Personal injury from fastener ejecting may occur.
WARNING:
Air is exhausted from the bottom of the tool. Direct bottom of the tool (exhausted air) away from operator, other
persons working in the vicinity, foreign matter and liquid.
WARNING:
Do not carry from hoses or use as a hammer.
WARNING:
Do not use in explosive atmosphere.
WARNING:
Ensure air hose is securely connected to avoid possible hose whipping.
WARNING:
Always disconnect air supply when tool is not in use to prevent accidental start-up.
WARNING:
Ensure there is adequate clearance for tool and operator hands.
WARNING:
Do not operate this tool without deflector, pintail catcher bag or pintail collection bottle in place.
CAUTION:
Do not use beyond the design intent.
The tool is shipped with red a plastic plug in the air inlet connector. The connector has a 1/4 - 18 female pipe thread to accept user air
hose fitting. The tool comes with oil and is ready to use.
1. Remove red plastic shipping plug from Swivel (A-249) (air inlet) and screw in your quick disconnect (air) fitting.
2. Connect tool to air hose with 90 psi. (6.2 bar) using clean, dry air. 3/8" (9.5 mm) minimum diameter air line is recommended.
Cycle tool five times by depressing and releasing actuator lever assembly (704343).
3. Disconnect air hose from tool.
4. Screw collet onto piston and slide anvil over collet and secure with retaining nut (211102). (See proper data sheet for further instructions).
Note: (See nose assembly disassembly on pg. 16 before assembling or disassembling nose assembly to tool).
5. Connect air supply.
RED SHIPPING PLUG
USER QUICK
DISCONNECT FITTING
AIR HOSE
GB731SHV5/LB68 INSTALLATION TOOL: SERIAL # 1001 & ABOVE
CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS.

HOW TO SET-UP THE GB731SHV5-LB68

MUST
read and understand all warnings and cautions.
the air lines and/or hydraulic hoses are not a trip hazard.
FLOW SPEED
CONTROL VALVE
AIR INLET
VACUUM
HEAD CYLINDER
Image may not reflect actual tool
8
NOSE ASSEMBLY
FASTENER
WORK
ACTUATOR
2/19 REV. 1/23

Advertisement

Table of Contents
loading

Table of Contents