Helm Panels –
Gauges will vary depending on Engine Package
Switches
Bilge Pump
Your Pro Line is equipped with an automatic bilge pump system with a manual override.
The pump is located in the bilge at the keel. The pump is mounted as low as possible. If
the pump runs for a long time it may mean that water is entering the bilge faster than the
pump can expel it. Investigate and correct the cause immediately. The automatic float
switch is wired directly to the battery terminal through an in-line fuse. Keep the bilge
area clean and free from debris that could clog ports. The helm switch overrides normal
automatic operation on the primary pump. Circuit breakers are located at the helm. Keep
the battery charged that the bilge pump is attached to. If the battery is discharged and
flooding occurs the boat could swamp, causing damage and possible loss of life or
property.
Lights
For operation at night, your Pro Line is equipped with navigation and anchor lights to
indicate your position to other boaters. While running after dark the nav. lights are
required to be on and visible to other boaters, visually verify operation and lack of
obstructions. Lights are also provided for the cockpit, helm and head.
Breaker Switches
The wiring on your Pro Line is protected by circuit breaker or fuse. Breakers are located
beside the switches or on the main breaker panel on the transom panel. If a device stops
working first suspect the circuit breaker is tripped (or fuse blown).
A tripped breaker will protrude from its set position, indicating that the circuit has been
overloaded. Turn off the device(s) on the circuit then reset the breaker by pushing in
once. If the breaker does not reset or if it resets and then pops out again after the device is
turned back on, then a short circuit exists or your device may be damaged, overloaded or
faulty. Correct the problem and then reset the breaker. If the breaker continues to pop
and you are certain the device, switch and wiring are in good repair; either the breaker is
too small for the load or is faulty. Reduce the load or replace the breaker.