Snap or slide T-nuts into the T-slot facing the conveyor. For the
Kentucky Gauge conveyors series RC or RH use one T-nut every 18
inches (recommended). Note: T-nuts may already be inserted.
Mount aluminum extrusion to conveyor by using M8 socket head cap
screws with washers and stand-offs. Stand-off length is designed
for Kentucky Gauge conveyors series RC and RH .
Note: Do not tighten the screws at this point to be able to align the
T-nuts with the conveyor mounting holes and to align the aluminum
extrusion in X direction when mounted to the conveyor
When all stand-offs of first aluminum guide section are mounted
adjust aluminum extrusion in X direction so that end of conveyor is
aligned with end of aluminum extrusion and tighten socket head cap
screws