AXIS A1214 Network Door Controller Kit
Specifications
Status
Green
Amber
Red
Power
Green
Amber
Relay
Green
Unlit
1.
Relay is active when COM is connected to NO.

Buttons

Control button
The control button is used for:
Resetting the product to factory default settings. See Reset to factory default settings on page 31.

Connectors

Network connector
RJ45 Ethernet connector with Power over Ethernet Plus (PoE+).
UL: Power over Ethernet (PoE) shall be over Ethernet IEEE 802.3af/802.3at Type 1 Class 3 or Power over Ethernet Plus (PoE+)
IEEE 802.3at Type 2 Class 4 power limited injector that provides 44–57 V DC, 15.4 W / 30 W. Power over Ethernet (PoE) has
been evaluated by UL with AXIS T8133 Midspan 30 W 1-port.
Reader connector
One 8-pin terminal block supporting both OSDP and Wiegand protocols for communication with the reader.
It can connect up to two OSDP readers (multi-drop) or one Wiegand reader. 500 mA at 12 V DC is reserved for all readers connected
to the door controller.
Configured for one OSDP reader
Function
DC ground (GND)
DC output (+12 V)
A
B
Configured for two OSDP readers (multi-drop)
Steady green for normal operation.
Steady during startup and when restoring settings.
Slow flash for failed upgrade.
Normal operation.
Flashes green/amber during firmware upgrade.
1
Relay active.
Relay inactive.
Pin
1
2
3
4
Note
Supplies power to reader.
Half duplex
Half duplex
25
Specifications
0 V DC
12 V DC, max 500 mA