Access Control; System - Axis A1214 User Manual

Network door controller kit
Hide thumbs Also See for A1214:
Table of Contents

Advertisement

AXIS A1214 Network Door Controller Kit
The web interface

Access control

Alarms
Device motion: Turn on to trigger an alarm in your system when it detects a movement of the door controller.
Casing open: Turn on to trigger an alarm in your system when it detects an open door controller case. Turn off this setting for
barebone door controllers..
External tamper: Turn on to trigger an alarm in your system when it detects an external tamper. For example, when someone
opens or closes the external cabinet.
• Supervised input: Turn on to monitor the input state and configure the end-of-line resistors.
-
-
Peripherals
Upgrade readers: Click to upgrade readers to a new firmware version. The feature can only upgrade supported readers when
they are online.

System

Time and location
Date and time
The time format depends on the web browser's language settings.
Note
We recommend you synchronize the device's date and time with an NTP server.
Synchronization: Select an option for the device's date and time synchronization.
• Automatic date and time (manual NTS KE servers): Synchronize with the secure NTP key establishment servers
connected to the DHCP server.
-
• Automatic date and time (NTP servers using DHCP): Synchronize with the NTP servers connected to the DHCP server.
-
• Automatic date and time (manual NTP servers): Synchronize with NTP servers of your choice.
-
• Custom date and time: Manually set the date and time. Click Get from system to fetch the date and time settings
once from your computer or mobile device.
Time zone: Select which time zone to use. Time will automatically adjust to daylight saving time and standard time.
Note
The system uses the date and time settings in all recordings, logs, and system settings.
Network
IPv4
To use parallel first connection, select Parallel first connection with a 22 KΩ parallel resistor and a 4.7
KΩ serial resistor.
To use serial first connection, select Serial first connection and select a resistor value from the Resistor
values drop-down list.
Manual NTS KE servers: Enter the IP address of one or two NTP servers. When you use two NTP servers,
the device synchronizes and adapts its time based on input from both.
Fallback NTP servers: Enter the IP address of one or two fallback servers.
Manual NTP servers: Enter the IP address of one or two NTP servers. When you use two NTP servers, the
device synchronizes and adapts its time based on input from both.
13