EdilKamin 809540 Installation, Use And Maintenance Manual page 28

Pellet fireplace
Table of Contents

Advertisement

- Relax function
Natural convection function with automatic power
limiting.
This function is available in all modes: automatic,
manual and crono.
Hold down the "M" button for two seconds to activate
the Relax function.
At display appears the symbol in the picture below.
Hold it down again to deactivate it.
The product reduces its power output and after a few
minutes switches the fan off too.
Pressing OK or "+" or "-" in this mode has no effect.
28
Menu
Press the "M" button to display the menu.
When the menu displays, the buttons have the
following functions:
"+" : scroll up
"-" : scroll down
press and release "OK": enter menu option
press and release "M": quit menu option
Press the ON/OFF button to confirm and return to the
main page.
USER INSTRUCTIONS
SCREW LOAD
STAND BY
PROGRAM
NIGHT
TIME-DATE
DISPLAY
LANGUAGE
BUZZER
INFO
TECH MENU
- Stand by
When the Stand by function is active, in automatic
and timer modes, the product shuts off when the
temperature setpoint is reached and turns on again
when the temperature drops.
When the Stand By function is not active, the product
sets itself to minimum power when the temperature
setpoint is reached
STAND BY
PROGRAM
NIGHT
TIME-DATE
DISPLAY
LANGUAGE
BUZZER
INFO
TECH MENU
To access the function from the main menu (as
indicated in the Menu section above), press the M
button. Scroll using the +/- buttons and select the
function by pressing OK.
Use the "+/-" buttons to select OFF or ON.
Press "M" to quit without saving.
Press "OK" for two seconds to confirm and return to
the previous menu level.
If you selected ON, the display shows the minutes for
which the product will continue running at minimum
power even when the temperature setpoint has been
reached.
Use the "+/-" buttons to increase or decrease this
time.
Press the ON/OFF button to confirm and return to the
main page.
The fireplace is programmed by default
with a delta of +/- 1 °C to optimise comfort.
The technician can change this setting
during commissioning to suit the needs of
the application.
The
display
rounded down, so that both 20.1°C and
20.9°C display as "20°"
E.g., with the room temperature set to 20° C, the
product will enter modulation mode/switch off when
a temperature of 21° C is reached and will switch on
again below 19° C.
shows
the
temperature

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pellkamin2 12809570

Table of Contents