3.5

Function faults

The following applies when lo-
cating and clearing faults:
Switch the vehicle off, remove
the key from the key switch
and disconnect the battery
plug!
Error code
1.2.5.2.
Brushes remain stopped
because the thermostatic
switch has been tripped.
1.2.6.1.
Brushes remain stopped
because the anti-blocking
system has been tripped.
1.2.6.3.
The brush attachment and
brush motors have been
switched off because the
anti-blocking system has
56

3.5.1 Error code table

In the case of system errors, a four-digit
error code appears in the left-hand op-
erating panel in addition to the service
indicator (wrench symbol).
Fault
The motor has overheated;
foreign bodies have possibly
jammed between the brush and
Foreign bodies (e.g. tape or
Foreign bodies between the
been tripped.
Cause
shaft (e.g. tape and such).
such) block the brushes.
brush head and vehicle.
The dots in the error/service code flash.
Clear the fault or note down the er-
ror/service code and inform your autho-
rized Hako dealer.
Solution
• Check the brushes for foreign bodies
and remove them, as necessary.
• Allow the motor to cool down.
• If the problem reoccurs, determine the
cause of overheating; contact an
authorized Hako service center, if
necessary.
• Check the brushes for foreign bodies
and remove them, as necessary.
• Check the brush head for foreign bodies
and remove them, as necessary.