Installing the 6033P-8R into a Rack

This section provides information on installing the SuperServer 6033P-8R into a
rack unit. If the 6033P-8R has already been mounted into a rack, you can skip
ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market,
which may mean the assembly procedure will differ slightly. The following is a
guideline for installing the 6033P-8R into a rack with the rack rails provided. You
should also refer to the installation instructions that came with the rack unit you
are using.

Identifying the Sections of the Rack Rails

You should have received two rack rail assemblies with the SuperServer 6033P-
8R. Each of these assemblies consist of two sections: an inner fixed chassis
rail that secures to the 6033P-8R (A) and an outer fixed rack rail that secures
directly to the rack itself (B). All screws and hardware mentioned in the instal-
lation steps should be included in the hardware kit.
To remove the fixed chassis rail (A), pull it out as far as possible - you should
hear a "click" sound as a locking tab emerges from inside the rail assembly and
locks the inner rail. Then depress the locking tab to pull the inner rail completely
out. Do this for both the left and right side rack rail assemblies.
Figure 2-1.
Locking Tab
Identifying the Sections of the Rack Rails
A
2-4
B