Electric Connection; Connection To The External Thermostat; Stove Calibration And Depression Measurement - Cadel ARCO 7 T1 Installer Manual

Hide thumbs Also See for ARCO 7 T1:
Table of Contents

Advertisement

The installation must be carried out by an authorised technician.
• According to the factory parameters, 1/2 of the generated heat is conveyed into the room where the stove is installed, while
the remaining 1/2 are conveyed through the left ducting pipe system.
• See the dedicated chapter of the USER MANUAL for the various adjustments.

6.12 ELECTRIC CONNECTION

Warning: the appliance must be installed by an authorized technician!
• The electric connection occurs through a cable with plug put in an electric socket which is able to support charge and tension
specific of every model, as described in the technical datas table (see a pag. 27).
• The plug must be easily accessible when the appliance is installed.
• Please further assure you that your network is endowed with an efficient earth connection: if it does not exist or if it is not
efficient, please endow you with one in compliance with the law.
• Connect the supply cable first on the back of the stove (see Fig. 43 and Fig. 44) and then at a wall electric socket.
Fig. 43 - Electric socket with master switch
• Do not use extension cables.
• If the feeder cable is damaged, it must be replaced by an authorized technician.
• When the stove is not going to be used for a long period of time, it advisable to remove the plug from the socket on the wall.
• An electrical connection to a UPS/ACCUMULATOR/ STABILISER must guarantee a voltage of at least 210 V without power
surges. Considering the variety of UPS on the market regarding size and construction qualities, we cannot guarantee operation
once the stove is connected to these devices.

6.13 CONNECTION TO THE EXTERNAL THERMOSTAT

The stove works through a thermostat probe placed in its inner. If you desire, the stove can be connected to an external room
thermostat. This operation must be executed by an authorized technician.
Connect the wires from the external thermostat to the "Term opt" terminal on the stove board. Activate the external thermostat
(default setting OFF) as indicated below:
• Press the "menu" button.
• Scroll with the arrows to "Settings".
• Select by pressing "menu".
• Scroll with the arrows again to "Ext.Thermostat".
• Select by pressing "menu".
• Press the - + buttons.
• To activate the external thermostat select "on".
• Press the "menu" button to confirm.

6.14 STOVE CALIBRATION AND DEPRESSION MEASUREMENT

This stove has a pickup point positioned on the tank in order to measure the depression of the combustion chamber and verify its
proper operation.
To do this, proceed as follows:
LUCE - ELLE - ARCO
Fig. 45 - Graphic display
Fig. 44 - Plug connected
19