Cadel ARCO 7 T1 BI-FLUX User Manual

Cadel ARCO 7 T1 BI-FLUX User Manual

Hide thumbs Also See for ARCO 7 T1 BI-FLUX:
Table of Contents

Advertisement

Quick Links

USER MANUAL
Pellet Stove
EN
new
ARCO 7 T1 - ARCO 7 T1 BI-FLUX
ARCO 9 T2 - ARCO 9 T2 BI-FLUX
ELLE PLUS 9 T2 - LUCE PLUS 9 T2
©2023 CADEL srl | All rights reserved - Tutti i diritti riservati

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ARCO 7 T1 BI-FLUX and is the answer not in the manual?

Questions and answers

Summary of Contents for Cadel ARCO 7 T1 BI-FLUX

  • Page 1 USER MANUAL Pellet Stove ©2023 CADEL srl | All rights reserved - Tutti i diritti riservati ARCO 7 T1 - ARCO 7 T1 BI-FLUX ARCO 9 T2 - ARCO 9 T2 BI-FLUX ELLE PLUS 9 T2 - LUCE PLUS 9 T2...
  • Page 2: Table Of Contents

    9 FUEL ............21 SUMMARY 9.1 FUEL ..............21 1 MANUAL SIMBOLOGY ........3 9.2 PELLET SUPPLY .............21 2 DEAR CUSTOMER ..........3 9.3 PELLET REFUELLING TIMER ........22 2.1 REVISIONS TO THE PUBLICATION ......4 10 VENTILATION ..........22 2.2 CARE OF THE MANUAL AND HOW TO CONSULT IT ...4 11 REMOTE CONTROL (OPTIONAL) ....22 SAFETY REQUIREMENTS ......5 12 SAFETY DEVICES AND ALARMS ....23...
  • Page 3: Manual Simbology

    2014/53/EU (RED - Radio Equipment directive) 2011/65/EU (ROhS) Hereby CADEL S.r.l. declares that the radio equipment type Easy Connect Plus + Navel Stand Alone is in compliance with Directive 2014/53/EU. According to (EU) No. 305/2011 regulation, the " Declaration of Performance" and "Declaration of Conformity" are available online,...
  • Page 4: Revisions To The Publication

    No part of this manual may be translated into other languages, adapted and/or reproduced, even in part, in other mechanical and/ or electronic form or media, for photocopies, recordings or other, without the prior written authorisation of CADEL S.r.l. The company reserves the right to make changes to the product at any time without prior notice. The owner company reserves its rights according to law.
  • Page 5: Safety Requirements

    SAFETY REQUIREMENTS • Installation, electrical connection, functional verification and maintenance must only be performed by qualified or authorised personnel. • Live electrical parts: disconnect the product from the 230V power supply before perfor- ming any maintenance operation. Only power the product after completing assembly. •...
  • Page 6: Cautions - Warranty Conditions

    • Childreen must be constantly overseen in order to assure that they do not play with the appliance. • During its running, the stove reaches high temperatures: keep away childreen and animals and for your safety please use appropriate fireproof devices, such as heat-protecting gloves. •...
  • Page 7: Warranty Conditions

    WARRANTY CONDITIONS The duration, conditions and limitations of CADEL S.r.l. can be found on the guarantee card enclosed with the device. The company guarantees the product, with the exception of elements subject to normal wear listed below, for a period of 2 (two) years from the date of purchase attested by: •...
  • Page 8: Spare Parts

    appliance, not attributable to original faults. Save for the legal or regulatory limits, the guarantee does not cover the containment of atmospheric and acoustic pollution. The company declines all liability for any damage which may be caused, directly or indirectly, to persons, animals or objects as a consequence of non compliance with any prescription specified in the manual, especially warnings regarding installation, use and maintenance of the appliance.
  • Page 9: Information For Management Of Electric And

    LEGENDA WHERE TO DISPOSE MATERIALS Metal If there is any, to be disposed of separately based on Glass A. OUTER CLADDING the material used: Tiles or ceramics Stone Glass ceramic (fire door): to be disposed of with If there is any, to be disposed of separately based on inert or mixed waste B.
  • Page 10: Wifi - Bluetooth Connection

    DESCRIPTION CODE MATERIAL SYMBOL DIRECTIONS FOR COLLECTION SORTED waste collection - WOOD BED WOOD WOOD - WOOD CAGE Check with the competent body on FOR 50 - WOOD PALLET how to dispose of this packaging at the recycling depot SORTED waste collection - CARDBOARD BOX PAPER CORRUGATED CARDBOARD...
  • Page 11: Use

    Fig. 3 - EASY CONNECT PLUS module Fig. 4 - EASY CONNECT PLUS display Fig. 5 - EASY CONNECT PLUS app The documentation for connecting the Wi-Fi and using the App are available online at the following addresses: https://www.cadelsrl.com/donwload-wi-fi/ http://www.free-point.it/it/downloads/ https://www.pegasoheating.com/it/documenti/ INTRODUCTION To have the best performance with the lowest consumption please follow the here descripted instructions.
  • Page 12: Control Panel Display

    Set values from 1 to 5 are defined by the manufacturer and they can be changed only by an authorized tech- nician. The product will be subject to expansion and contraction during the ignition and cooling stages, therefore slight creaking noises may be heard. This is perfectly normal as the structure is made of laminated steel and must not be considered a defect.
  • Page 13: Settings Menu

    Sleep setting (see relative chapter) SETTINGS MENU The SETTINGS menu allows to act on the boiler operating mode: a - Language b - Cleaning (displayed only when the boiler is switched off) c - Screw Loading (displayed only when the boiler is switched off) d - Tone e - Ext.Thermostat (activation) f - Auto-Eco (activation)
  • Page 14 e - Ext.Thermostat (see relative chapter) f - Auto-Eco activation To select the Auto-Eco function act as follows: • Press the “menu” button. • Scroll to “Settings” using the arrows • Press “menu” to confirm. • Scroll to “Auto-Eco activation" using the arrows. •...
  • Page 15: Info Menu

    • Press “menu” to confirm. • Select the test to be performed with the + - keys • Press “menu” to confirm and “esc” to exit k - “Chimney Sweep Function" To activate the “Chimney Sweep Function” function act as follows: •...
  • Page 16: Switch Off (On Panel: Off With Flashing Flame)

    the stove during ignition stage if dense white smoke is present. If after some months the flame appears weak and/or orange colored or the glass tends to blackens and the burning pot to become encrusted, clean the stove, clean the fume conduit and the chimney flue. ATTENTION! Make sure pellets and ash have not accumulated in the brazier due to failed ignition.
  • Page 17: Programmed Mode (Timer) - Main Menu

    Fig. 12 - Display Fig. 13 - Display Fig. 14 - Display With function “1” or "2" or "3" or "4" or "5" the fan is forced to work at the selected output. (For example: by setting “3”, even if the fan is set to heat output 5 it will work as if set to heat output “3”, etc.).
  • Page 18: Programming Examples

    The next step proposes a shutdown time of 10 minutes above that set for start-up: press the + key and adjust the shutdown time, confirm with the “menu” key. Subsequently the system proposes the days of the week in which to activate or deactivate the previously set timer. With the - or + key highlight with the white background the day in which one wishes to activate the timer and confirm with the “menu”...
  • Page 19: Sleep Function (Main Menu)

    • After 5 minutes from the beginning of the switch-off procedure. 8.15 SLEEP FUNCTION (MAIN MENU) The sleep function is activated only when the boiler is switched on and allows to quickly set a time at which the product must switch off.
  • Page 20: Pellets Recipe

    LEGENDA Fig. 21 Smoke Outlet Combustion Air Intake Inspection cap 8.17 PELLETS RECIPE (SEE SECTION H SETTINGS MENU A PAG. 13) Changes to be made with the support of the authorised technician. Activates only with the Easy Set function disabled, "SET: 0" ! This function is for adapting the stove to the pellets that are being used.
  • Page 21: Fuel

    FUEL FUEL • Use top-quality pellets because they have influence in the calorific value and in ash remains. • Not adequate pellets cause a bad combustion, a frequent burning pot obstruction and exhaust conduits obstruction. Further it decreases the calorific value, soils the glass and increases consumptions and ash and unburnt granules quantity. Humid pellets cause a bad combustion and running, so please assure you that they are stored in dry places and far at least one meter from the stove and/or any other source of heat.
  • Page 22: Pellet Refuelling Timer

    PELLET REFUELLING TIMER This stove is equipped with a safety timer that activates after the pellet hopper door has been open for 90 seconds during reloa- ding (see Fig. 24 and Fig. 26). After 90 seconds, the stove goes into "A05" depression alarm and proceeds to switch off. Wait until it switches off, then light it again.
  • Page 23: Safety Devices And Alarms

    Used batteries contain metals which are harmful for the environment; they must therefore be disposed of separately in the special containers. Fig. 28 - Remote control LEGEND Fig. 28 Button 1 Increase the desired temperature (5÷35 °C) Button 2 Decrease the desired temperature (35÷5 °C) Button 3 On / off Button 4...
  • Page 24: Gear Motor

    12.6 GEAR MOTOR If the gear motor stops, the boiler will continue to run until the flame goes out due to lack of fuel and until a minimum level of cooling is reached. 12.7 TEMPORARY POWER CUT If the power cut lasts less than 10” the boiler returns to its previous operating status; if it lasts more it carries out a cooling/restart cycle.
  • Page 25: Alarm Reset

    12.11 ALARM RESET To reset the alarm you must keep the 1 (ESC) button pressed for some time. The stove performs a check to determine whether the warning cause is still present. If this is the case, the warning will be shown again, otherwise the stove will switch to the OFF position. If the warning is still present, contact a service centre.
  • Page 26: Hopper Cleaning

    Fig. 31 - Burning pot extraction Fig. 32 - Burning pot cleaning • Extract the burning pot (see Fig. 31) from its seat and empty it from the ash. • If necessary clean with a pointed object the holes obstructed by encrustations (see Fig. 32). Fig.
  • Page 27: General Cleaning

    flue and chimney pot. He will also check their eficiency and will release a written declaration of the safety of the appliance. This operation must be executed at least once a year. 13.6 GENERAL CLEANING For cleaning external and inner parts of the stove do not use steel wools, muriatic acid or other corrosive and abrasive materials. 13.7 CLEANING OF PAINTED METAL PANELS To clean painted metal panels use a soft cloth.
  • Page 28: Checking The Inner Components

    After removing the plugs from the power socket, open the fusebox cover with a screwdriver and replace the fuses if necessary (3.15 A delayed) - seek assistance from an authorised and qualified technician. 13.12 CHECKING THE INNER COMPONENTS ATTENTION! The internal electromechanical components must only be checked by qualified personnel whose technical expertise includes combustion and electricity.
  • Page 29 PROBLEM CAUSE SOLUTION INTERVENTION The stove is without Check if the plug is connected. power supply Burned protection fuse in the electric Replace the protection fuses in the electric socket (3.15A-250V). socket The control display Faulty control Replace the control display. does not switch on display Faulty flat cable...
  • Page 30 PROBLEM CAUSE SOLUTION INTERVENTION Check as following: probable obstructions of the combustible air Not sufficient com- inlet from the back or from the bottom of the stove; burning pot bustion air obstructed holes with too ash remains. Have the fan blades and auger cleaned.
  • Page 31: Technical Documentation For Local Space Heaters According To Commission Regulations (Eu) 2015/1185 - (Eu) 2015/1186 (Product Fiche)

    TECHNICAL DOCUMENTATION FOR LOCAL SPACE HEATERS ACCORDING TO COM- MISSION REGULATIONS (EU) 2015/1185 - (EU) 2015/1186 (PRODUCT FICHE) CADEL srl - Via Martiri delle Libertà 74 - 31025 Santa Lucia di Piave Manufacturer (TV) - Italy CADEL: ELLE PLUS 9 T2 - LUCE PLUS 9 T2...
  • Page 32 TECHNICAL DOCUMENTATION FOR LOCAL SPACE HEATERS ACCORDING TO COM- MISSION REGULATIONS (EU) 2015/1185 - (EU) 2015/1186 (PRODUCT FICHE) CADEL srl - Via Martiri delle Libertà 74 - 31025 Santa Lucia di Piave Manufacturer (TV) - Italy CADEL: Trademak: model identifier...
  • Page 33 NOTE...
  • Page 34 NOTE...
  • Page 35 NOTE...
  • Page 36 Rev. 00- 2023 CADEL srl www.cadelsrl.com 31025 S. Lucia di Piave - TV www.free-point.it Via Martiri della Libertà, 74 - Italy www.pegasoheating.com Tel. +39 0438 1520200...

Table of Contents