Supero SuperServer 5015B-MF User Manual page 38

High-end single processor 1u rackmount server
Table of Contents

Advertisement

S
S
UPER
ERVER 5015B-MF User's Manual
4.
Align pin1 of the CPU (the corner
marked with a triangle) with the
notched corner of the CPU socket.
5.
Find the corner of the CPU that
has a semi-circle cutout below a
gold dot (CPU key). This corner
should be aligned with the cutout
on the socket (socket key).
6.
Once aligned, carefully lower
the CPU straight down into the
socket. Do not drop the CPU on
the socket, do not move the CPU
horizontally or vertically and do not
rub the CPU against any surface
or any of the contacts, which may
damage the CPU and/or contacts.
7.
With the CPU in the socket, in-
spect the four corners of the CPU
to make sure that it is properly
installed.
8.
Use your thumb to gently push the
load lever down until it snaps into
the retention clasp.
9.
If the CPU is properly installed
into the socket, the PnP cap will
be automatically released from the
load plate when the lever locks.
Remove the cap. Repeat steps to
install a second CPU if desired.
Warning! Keep the plastic PnP cap.
The serverboard must be shipped with
the PnP cap properly installed to protect
the CPU socket. Shipment without the
PnP cap properly installed will void the
warranty.
Gold dot
Socket key
CPU key
Notched corner
Load lever
CPU installed in socket
PnP cap released
from load plate
5-6
CPU pin 1