Control *
RemoteAutoRecog
MIG CurrentDisp
WFMotorWarnLev
WF End Step
AutoWireInch
Gas Guard
ArcVoltage
SubFeederLength
* When connecting a remote control device to the power source in MMA/CC/CV welding,
you don't need to make adjustments to this setting. Remote control device is automatically
recognised, when USER option is selected (default) and RemoteAutoRecog=ON.
© Kemppi Oy / R05
USER, PANEL,
Factory settings is USER
REMOTE, GUN.
ON, OFF.
Factory setting is ON
ON, OFF
Factory setting is OFF
1.5...5.0 A
Factory setting is 3.5A
ON, OFF
Factory setting is OFF
ON, OFF
Factory setting is ON
ON, OFF
Factory setting is OFF
ON, OFF
Factory setting is OFF
10...25 m
Factory setting is 10 m
This setting affects the XF 37 (or XF 38)
control panel remote control unit selection.
USER: User can select the remote control
device at XF 37 (or XF 38) panel
PANEL: Selection is locked to PANEL, and
user can not select the remote device at
XF 37 panel.
REMOTE: Selection is locked to HAND
REMOTE device.
GUN: Selection is locked to GUN REMOTE
device.
Automatic remote control unit recognition.
ON: Remote control units are recognized.
Wire feeder panel XF 37 (or XF 38) jumps
to PANEL selection, if the selected remote
control unit disappears.
OFF: Remote control units are not
recognized. Remote control unit selection
remains unchanged if the selected remote
control unit disappears.
ON: Displays amperage (A) preset values
OFF: Displays wire feed speed (m/min).
The alarm level of wire feed motor current.
Check/service wire feed mechanism,
adjustment and gun components.
ON: The filler wire steps forward at the end
of the welding cycle.
OFF: Filler wire remains static at the end of
the welding cycle.
Automatic SuperSnake Wire Inch feature.
When ON, the Wire Inch button drives the
filler wire automatically up to SuperSnake.
Turns the gas guard on and off, provided
that one is installed.
Measured and calculated arc voltage.
This must be calibrated using voltage
measurement cable.
If ON, welding panel and subfeeder/R30
shows arc voltage value in voltage display.
Sub feeder length selection for arc voltage
calculation.