Crater 4T Timer
Creep Start
StartPower
ADVANCED FUNCTIONS
WisePenet
Penet%(123A)
WiseFusion
WiseFusion%
MatchFunc *
MinilogLevel
MatchMemChannel
* MatchFunc is a function that allows you to use two pre-defined sets of welding parameters
during welding. You can toggle between these parameter sets by pressing the welding gun
trigger briefly without having to stop welding.
SYSTEM CONFIG MENU
Water Cooling
Cable Length
FineCalib
System Clock
Device List
© Kemppi Oy / R05
On, OFF
Factory setting is OFF
10...99 %
Step: 1
OFF, CURVE (OFF=100%)
Factory setting is CURVE
-9...+9
Factory setting is 0
ON, OFF
-30...+30 %
Factory setting: 0 %
ON, OFF
10...60 % or
Factory setting is CURVE
CURVE
Minilog, MatchCh
Default is OFF
OFF
-99...+125 %
Factory setting is 20
0...9
Factory setting is 0
ON, OFF, AUTO
Factory setting is AUTO
10...100 m
Step: 5
Factory setting is 10m
0V/100A...10V/100A Step: 0.1 V
Factory setting is 1.0V/100A
System Clock Settings
Shows a list of connected devices.
ON: if 4T is selected, crater filling will last
at least time that has been adjusted by
CraterTime or as long as trigger is pressed.
OFF: if 4T is selected, crater filling will last
as long as trigger is pressed.
CURVE means that the creep start value
comes from welding program.
Adjusts arc ignition.
Penetration control selection
WisePenetration percent setting. Set
penetration current.
WiseFusion selection
When WiseFusion is ON, it controls the
amount of short circuits in the arc. The
lower the value, the less short circuits in
the arc, and the higher the value, the more
short circuits in the arc.
Selects the type of function for toggling
between two sets of welding parameters
during welding:
Minilog=percentage of base current
MatchCh=alternative memory channel
Sets the alternative current level to a
percentage of the base current
Sets the pre-defined memory channel,
where the alternative set of parameters is
stored
Water cooler control.
ON: Water cooler is always ON
OFF: Water cooler is always OFF
AUTO: Water cooler starts when welding
starts and turns off after a delay when
welding stops.
Welding cable loop length setting for
optimising arc control.
Fine Tuning Calibration Point. Compensation
for varying cable resistance.
EN