Kemppi FastMig X 350MV Manual page 17

Table of Contents

Advertisement

DOUBLE PULSE MIG
WFSpeed
0.7...25 m/min *
WFS-Max
WFS-Min
FineTuning
-9.0...+9.0
FineTuningMax
-9.0...+9.0
FineTuningMin
-9.0...+9.0
Dynamics
-9...+9
Pulse Current
-10...+15%
DPulseAmp
0.1...3.0 m/min
DPulseFreq
0.4...8.0 Hz
WISEROOT+
WFSpeed
1.5...8.0 m/min *
WFS-Max
WFS-Min
FineTuning
-9.0...+9.0
FineTuningMax
-9.0...+9.0
FineTuningMin
-9.0...+9.0
* Different welding programs may further restrict the value range.
WISETHIN+
WFSpeed
0.7...25 m/min *
WFS-Max
WFS-Min
FineTuning
-9.0...+9.0
FineTuningMax
-9.0...+9.0
FineTuningMin
-9.0...+9.0
Dynamics
-9...+9
© Kemppi Oy / R05
Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed < 5 m/min, and
by 0.1, when WFSpeed > 5 m/min
Sets the limit for maximum WFSpeed
Sets the limit for minimum WFSpeed
Factory setting is 0.0
Adjusts the base current of the curve (arc length) in
( = curve point)
certain limits
Step: 0.5
Sets the limit for maximum arc length
Step: 0.5
Sets the limit for minimum arc length
Factory setting is 0
Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
Factory setting
Reduces (-) or raises (+) the pulse current of the curve
is 0%
Factory setting is
Adjusts the amplitude of the WFSpeed by steps of 0.1.
CURVE
Value comes from welding program.
Factory setting is
Adjusts the frequency of the double pulse by steps of 0.1.
CURVE
Value comes from welding program.
Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed < 5 m/min,
and by 0.1, when WFSpeed > 5 m/min
Sets the limit for maximum WFSpeed
Sets the limit for minimum WFSpeed
Factory setting is 0.0
Adjusts the base current of the curve (heat of the arc)
( = curve point)
within certain limits.
Step: 0.5
Sets the limit for maximum heat of the arc
Step: 0.5
Sets the limit for minimum heat of the arc
Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed < 5 m/min, and
by 0.1, when WFSpeed > 5 m/min
Sets the limit for maximum WFSpeed
Sets the limit for minimum WFSpeed
Factory setting is 0.0
Adjusts the arc voltage of the curve (arc length) within
( = curve point)
certain limits
Step: 0.5
Sets the limit for maximum arc length
Step: 0.5
Sets the limit for minimum arc length
Factory setting is 0
Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
EN
15

Advertisement

Table of Contents
loading

Table of Contents