Download Print this page
Panasonic CS-Z25UFRAW Operating Instructions Manual

Panasonic CS-Z25UFRAW Operating Instructions Manual

Hide thumbs Also See for CS-Z25UFRAW:

Advertisement

Operating Instructions
Air Conditioner
Model No.
Indoor Unit
CS-Z25UFRAW
CS-Z35UFRAW
CS-Z50UFRAW
Outdoor Unit
Single Split
CU-Z25UBRA
CU-Z35UBRA
CU-Z50UBRA
* Outdoor Unit
Multi Split
CU-2Z50UBR
Operating Instructions
Air Conditioner
Before operating the unit, please read these operating
instructions thoroughly and keep them for future reference.
The included Installation Instructions should be kept and read
by the installer before installation.
Remote control is packaged in the indoor unit and removed
by the installer before installation.
* Kindly consult authorised dealer for connectivity validity.
ACXF55-20720

Advertisement

loading

Summary of Contents for Panasonic CS-Z25UFRAW

  • Page 1 Operating Instructions Air Conditioner Model No. Indoor Unit Outdoor Unit Single Split CS-Z25UFRAW CS-Z35UFRAW CU-Z25UBRA CS-Z50UFRAW CU-Z35UBRA CU-Z50UBRA * Outdoor Unit Multi Split CU-2Z50UBR Operating Instructions Air Conditioner Before operating the unit, please read these operating instructions thoroughly and keep them for future reference.
  • Page 2 Console designed for discreet integration on walls, provides maximum comfort without compromising performance. Flexibility to connect Single Split System or Multi Split System Air Conditioner to suit your needs. For complete product features, please refer to catalogue. Use remote control within 8 m from the remote control receiver of the indoor unit.
  • Page 3: Table Of Contents

    Thank you for purchasing Panasonic Air Conditioner. Table of contents Safety precautions .... 4-15 How to use ......16-17 To learn more ....... 18 Cleaning instructions ... 19 Troubleshooting ....20-22 Information ......23 Accessories • Remote control • AAA or R03 batteries × 2 •...
  • Page 4: Safety Precautions

    Safety precautions To prevent personal injury, injury to others WARNING or property damage, please comply with the following: Incorrect operation due to failure to follow instructions below may cause harm or Indoor unit and outdoor unit damage, the seriousness of which is This appliance is not intended for classifi...
  • Page 5 Do not install the unit in a potentially If the supply cord is damaged, explosive or fl ammable atmosphere. it must be replaced by the Failure to do so could result in fi re. manufacturer, service agent or similarly qualifi ed persons in order to Do not insert your fi...
  • Page 6 Safety precautions Prevent water leakage by ensuring CAUTION drainage pipe is: -Connected properly, -Kept clear of gutters and Indoor unit and outdoor unit containers, or Do not wash the indoor unit with -Not immersed in water water, benzine, thinner or scouring After a long period of use or use with powder to avoid damage or any combustible equipment, aerate...
  • Page 7 Precaution for using R32 WARNING refrigerant The basic installation work procedures are the same as conventional refrigerant This appliance is fi lled with R32 (R410A, R22) models. (mild fl ammable refrigerant). Since the working pressure is If the refrigerant is leaked and higher than that of refrigerant R22 exposed to an external ignition models, some of the piping and...
  • Page 8 Safety precautions • Any part of refrigerating circuit c) Able to understand and to apply (evaporators, air coolers, AHU, in practice the requirements condensers or liquid receivers) or in the national legislation, piping should not be located in the regulations and Standards; and, proximity of heat sources, open d) Continuously undergo regular fl...
  • Page 9 2. Servicing 2-2. Work • Prior to beginning work on 2-1. Service personnel systems containing fl ammable • The system is inspected, regularly refrigerants, safety checks are supervised and maintained by necessary to ensure that the risk a trained and certifi ed service of ignition is minimised.
  • Page 10 Safety precautions 2-3. Checking for presence of 2-5. No ignition sources refrigerant • No person carrying out work in • The area shall be checked with an relation to a refrigeration system appropriate refrigerant detector which involves exposing any pipe prior to and during work, to work that contains or has contained ensure the technician is aware of...
  • Page 11 2-7. Checks to the refrigeration 2-8. Checks to electrical devices equipment • Repair and maintenance to • Where electrical components are electrical components shall include being changed, they shall be fi t initial safety checks and component for the purpose and to the correct inspection procedures.
  • Page 12 Safety precautions 3. Repairs to sealed components 4. Repair to intrinsically safe • During repairs to sealed components components, all electrical supplies • Do not apply any permanent shall be disconnected from the inductive or capacitance loads to equipment being worked upon prior the circuit without ensuring that to any removal of sealed covers, this will not exceed the permissible...
  • Page 13 7. Leak detection methods 8. Removal and evacuation The following leak detection • When breaking into the refrigerant methods are deemed acceptable for circuit to make repairs – or for all refrigerant systems. any other purpose – conventional • No leaks shall be detected when procedures shall be used.
  • Page 14 Safety precautions 9. Charging procedures 10. Decommissioning • In addition to conventional • Before carrying out this procedure, charging procedures, the following it is essential that the technician requirements shall be followed. is completely familiar with the -Ensure that contamination of equipment and all its details.
  • Page 15 i) Do not exceed the maximum • Cylinders shall be complete working pressure of the cylinder, with pressure relief valve and even temporarily. associated shut-off valves in good j) When the cylinders have been working order. fi lled correctly and the process •...
  • Page 16: How To Use

    Single Single split system How to use Multi Multi split system POWER To adjust airfl ow direction TIMER Upper nanoeX AIR SWING direction Indicator • To change the horizontal airfl ow direction, move the vertical vane manually before starting operation. To adjust fan speed AUTO FAN SPEED...
  • Page 17 See "To learn more..." for details. To set the timer 2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset times. • To cancel ON or OFF timer, press TIMER to select respective then TIMER press...
  • Page 18: To Learn More

    Single Single split system To learn more... Multi Multi split system Operation mode • It is possible to operate the indoor units individually or simultaneously. The priority of operation is placed on the fi rst unit that turned on. • During operation, HEAT and COOL modes cannot activate at the same time for different indoor units.
  • Page 19: Cleaning Instructions

    Cleaning instructions To ensure optimal performance of the unit, cleaning has to be carried out at regular intervals. Dirty unit may cause malfunction and you may see error code “H 99”. Please consult authorised dealer. • Switch off the power supply and unplug before cleaning. •...
  • Page 20: Troubleshooting

    Troubleshooting The following symptoms do not indicate malfunction. Symptom Cause POWER indicator blinks before the unit is • This is a preliminary step in preparation for the switched on. operation when the ON timer has been set. When ON Timer is set, the unit may start earlier (up to 35 minutes) before the actual set time in order to achieve the desired temperature on time.
  • Page 21 When... ■ The remote control is missing or a malfunction has occurred 1.Press the button once to use in AUTO mode. 2. Press and hold the button until you hear 1 beep, then release to use in forced COOL mode. 3.
  • Page 22 Troubleshooting How to retrieve error codes If the unit stops and the TIMER indicator blinks, use the remote control to retrieve the error code. Press until you hear beep Press for TIMER TIMER sound, then write down the 5 seconds error code TIMER TIMER...
  • Page 23: Information

    Information Information for Users on Collection and Disposal of Old Equipment and used Batteries [Information on Disposal in other Countries outside the European Union] These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal.
  • Page 24 Panasonic Corporation 1006 Kadoma, Kadoma City, Osaka, Japan Website: http://www.panasonic.com © Panasonic Corporation 2018 ACXF55-20720 Printed in Malaysia PC0518-0...