M8100A Series Arbitrary Waveform Generators Getting Started Guide
5
Screw torque will be each screw 1.7 Nm.
6
Place the 8x connectors of the M8199A-ILV on the plugs available on
the M8199A front panel.
7
Screw the nut of the connector by hand until you are sure that the nut
runs in the thread.
8
Use the torque wrench (8710-1765) to fix the nut with the right torque
(0.9 Nm) at all 8 connectors of the M8199A-ILV. The required torque
for 1.85 mm connectors is 0.9 Nm (8lb-inch).
9
Mount the M8199A instrument together with M8199A-ILV back to the
AXIe Chassis.