To disable the Check-Weighing function enter zero into both limits by pressing the
[Func/Set] key when the current limits values are displayed during the setting procedure,
then pressing [Tare/↵] to store the zero values.
The values set for the check-weighing will remain in memory when the weighing units or
the function changes to parts counting but will not be active. The will become active again
when the weighing unit or parts counting that was active at the time the limits were set is
reactivated.
6.8

ACCUMULATED TOTAL

The scale can be set to accumulate manually by pressing the [CHK/ Print]
key or automatically when a weight is removed from the scale.
accumulation function is available when weighing or when counting parts.
However the memory is cleared if the weighing units or functions are
changed.
When the weight (or count) displayed is stored in memory the display will
show "ACC 1" and then the total in memory for 2 seconds before returning to
weighing. The RS-232 interface will output to a printer or PC.
Remove the weight, allowing the scale to return to zero and put a second
weight on. When this value is stored, the display will show "ACC
the new total and finally the value of the second weight. Repeat as necessary
to add all the values needed to the memory.
To view the total in memory press the [CHK/Print] key when there is no
weight on the scale. The display will show the number of entries and the
total.
To clear the memory (set the value to zero) press the [Power/ST] key during
the time the totals are being displayed, "Clear" will flash on the display for 2-3
seconds and then return to the usual weighing display.
6.9
PERCENT WEIGHING
The scale can be set to perform percent weighing.
The scale will use a mass on the platform as the 100% reference weight.
Press the [Func/Set] key to select the weighing mode.
Using the directional buttons ⭡ or ⭣, scroll through to the percent weighing
mode, "Percent" will be shown on the display. Press [Tare/↵] to confirm.
Once in percent weighing mode the "%" indicator will appear on the right-
hand side of the display.
The