  • Page 3: Table Of Contents

    COMMUNICATION PARAMETERS ............16 8.2.1 COMMUNICATION ADDRESS ............... 16 8.2.2 BAUD RATE.................... 17 8.2.3 A/D COUNT .................... 17 RS-232 INTERFACE..................18 10.0 LOAD CELL CONNECTION................19 11.0 ERROR MESSAGES AND TROUBLE-SHOOTING........20 12.0 SERVICE INFORMATION ................21 © Adam Equipment Company 2008...
  • Page 4 ©Adam Equipment Company 2008...
  • Page 5: Introduction

    • Supplied complete with the AE 202 Indicator in plastic housing • Precision load cells for accurate weighing results every time • Handles for portability • Low profile beams to allow easy weighing of pallets • 2 beams per set ©Adam Equipment Company 2008...
  • Page 6 The AE-202 Indicator offers: • Large clear red LED Display, highly visible in all work areas • Simple user-friendly operations • Full range tare • Manual or automatic memory accumulation facility • Selectable automatic power off • Bi-directional RS-232 Interface •...
  • Page 7: Specifications

    Beam Dimension 1200 x 120 x 85 mm. 47.2” x 4.7” x 3.3” Net weight 45 kg / 99 Lb. Functions Weighing, Manual and automatic memory accumulation facility, Manual and automatic print, Automatic power off Counting ©Adam Equipment Company 2008...
  • Page 8: Unpacking The Scale

    • Ensure both the beams are connected. • Switch the main supply to ON. • Read this User Manual before starting the weighing operation. Place the pallets on the beams for weighing. • ©Adam Equipment Company 2008...
  • Page 9: Keyboard And Display

    KEYBOARD AND DISPLAY The AE-202 indicator has the following LED symbols: Power Main power is applied to the indicator Lo Bat Battery needs charging Count Parts counting mode Auto The automatic accumulation function is active Stable The weight is stable A weight has been tared, the display is showing the net weight.
  • Page 10: Operations

    230VAC power supply. • To turn on the AE-202, turn on the power switch at the rear of the indicator and then press the [On/Off] key. • The display will show the software revision then a self test, showing the segments are all working.
  • Page 11: Accumulation Control Setting

    The next accumulation is available only after displaying value is less then minimum weighing value set in user parameters section 7.0. Alternatively the indicator can be set to do an automatic memory accumulation, see section below. ©Adam Equipment Company 2008...
  • Page 12: Automatic Memory Accumulation

    [Acc/ ] key, the accumulated value will be printed if communication address is 99. • When the number “n 52” is displayed and before the total is shown, press [Zero] to clear the accumulated value. ©Adam Equipment Company 2008...
  • Page 13: Switch Between Kilogram To Pound

    If the count function is enabled as explained in section 8.0, the following operation is available. • In weighing mode when zero is displayed, press the [On/Off] key to enter count mode. • The display will show –SanP- and the Count indicator will be on. ©Adam Equipment Company 2008...
  • Page 14: High Resolution Display

    In weighing mode, press the [x10 /Inc] to enter high resolution display (10 times) and the right most decimal point will be lit. Press the [x10 /Inc] key again to return to the normal weighing display. ©Adam Equipment Company 2008...
  • Page 15: Battery Operation

    BATTERY LIFE The battery life of 6V / 4Ah built-in maintain-free battery supplied with the indicator is 48 hours if it is fully charged. ©Adam Equipment Company 2008...
  • Page 16: Calibration

    If you need to calibrate then the indicator has to be openned for a link to be fitted to the PCB jumper marked “EN” Contact your supplier or Adam Equipment for details. After calibration the link should be returned to “DS”...
  • Page 17: User Parameters

    = 1: With count function enabled d = 0: No accumulation function. d = 1: With accumulation function enabled. E = 0: No high resolution display function E = 1: With high resolution X10 display function enabled. ©Adam Equipment Company 2008...
  • Page 18: Filter

    = Manual print mode with [Acc / Once the value is entered, press [Kg/lb /Set] to move to the next parameter for setting the baud rate. Store the desired settings by pressing [Kg/lb /Set] and move to the next parameter ©Adam Equipment Company 2008...
  • Page 19: Baud Rate

    A/D Count. 8.2.3 A/D COUNT Press [Acc / ] to show the A/D Count or press [Kg/lb /Set] to return to normal weighing. When viewing the A/D count press [Kg/lb /Set] to return to normal weighing. ©Adam Equipment Company 2008...
  • Page 20: Rs-232 Interface

    : w w w w w . w u u <cr><lf> 1 2 3 4 5 6 7 8 9 1011121314 15 16 i.e. _ _ 1 2 : _ _ 5 4 . 5 K G <cr><lf> ©Adam Equipment Company 2008...
  • Page 21: Load Cell Connection

    Load cell supply voltage: 5 VDC Pin 1-2: +E Load cell excitation positive Pin 4-5: -E Load cell excitation negative Pin 7: +S Load cell output positive Pin 8: -S Load cell output positive Pin 3: GND Load cell cable shield ©Adam Equipment Company 2008...
  • Page 22: Error Messages And Trouble-Shooting

    “POWER” LED on the front of the indicator is lit. Test voltage on the battery to ensure that it is charging above 6 volts. Check load cell and RS232 connection to see if any are shorted. ©Adam Equipment Company 2008...
  • Page 23: Service Information

    Include any recent history of the unit. For example: -Has it been working since it’s delivered -Has it been in contact with water -Damaged from a fire -Electrical Storms in the area -Dropped on the floor, etc. ©Adam Equipment Company 2008...
  • Page 24: Adam Equipment Company

    ©Adam Equipment Company 2008...
  • Page 25 During the warranty period, should any repairs be necessary, the purchaser must inform its supplier or Adam Equipment Company. The company or its authorised Technician reserves the right to repair or replace the components at the purchaser’s site or any of its workshops depending on the severity of the problems at no additional cost.
  • Page 26 ©Adam Equipment Company 2008...
  • Page 27 Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device. Changes or modifications not expressly approved by Adam Equipment could void the user's authority to operate the equipment. WEEE COMPLIANCE...
  • Page 28 For a complete listing of all Adam products visit our website at www.adamequipment.com © Copyright by Adam Equipment Co. Ltd. All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment.

This manual is also suitable for:

Aelp 2000Aelp 1000

Table of Contents