Appendix A. Specifications; Thermistor; Strain Gage; Table 7 - Strain Gage Specifications - Geokon 4200 Series Instruction Manual

Vibrating wire strain gages
Hide thumbs Also See for 4200 Series:
Table of Contents

Advertisement

22

APPENDIX A. SPECIFICATIONS

A.1 Strain Gage
Model
4200
Range
(Nominal)
1.0 µε¹
Resolution
Calibration
Accuracy
Typical
0.98
Batch Factor
Batch Factor
Accuracy
System
Accuracy
Stability
Linearity
Thermal
3
Coefficient
Frequency
450-1200
Range Hz
6.125 ×
Dimensions
(gage)
0.750"
(Length ×
155 × 19
Diameter)
mm
0.875 ×
0.875"
Dimensions
22 × 22
(coil)
mm
Coil
180Ω
Resistance
Temperature
Range
Notes:
¹ Possible resolution depends on the readout; the figures in Table 7 pertain to the GK-404.
² System Accuracy takes into account hysteresis, nonlinearity, misalignment, batch factor
variations, and other aspects of the actual measurement program. System Accuracy to ±1.0% FS
may be achieved through individual calibration of each strain gage.
Model 4200HT-T high temperature strain gage has a Thermal Coefficient of 17.3 µε/°C
3
A.2 Thermistor
Range: -80 to +150 °C. Accuracy: ±0.5 °C. (See Appendix C for more information.)
4202
4204
0.4 µε¹
1.0 µε¹
0.91
N/A
1400-
800-1600
3500
2.250 ×
4.125 ×
0.625"
0.750"
57 × 16
105 × 19
mm
mm
50Ω
180Ω
-20 to +80° C

Table 7 - Strain Gage Specifications

4210
4212
3000 µε
0.4 µε¹
0.4 µε¹
±0.1% FSR
0.95
N/A
±0.5% FSR
±2.0% FSR²
0.1% FS/yr
0.5% FSR
12.2 µε/°C
3
1400-
1400-
3500
3500
10.250 ×
12.250 ×
2"
2"
260 × 50
311 × 50
mm
mm
N/A
180Ω
180Ω
4214
4200HT
0.4 µε¹
1.0 µε¹
N/A
0.98
1400-
450-1200
3500
14.250 ×
6.125 ×
2"
0.750"
362 × 50
155 × 19
mm
mm
0.875 ×
0.875"
22 × 22
mm
180Ω
120Ω
-20 to
+200° C