Figure 10 - Lightning Protection Scheme - Geokon 4200 Series Instruction Manual

Vibrating wire strain gages
Hide thumbs Also See for 4200 Series:
Table of Contents

Advertisement

10
Suggested Lightning Protection Options:
If the gage is connected to a terminal box or multiplexer, components such as plasma surge
arrestors (spark gaps) may be installed in the terminal box/multiplexer to provide a measure
of transient protection. Terminal boxes and multiplexers available from Geokon provide
locations for the installation of these components.
Lighting arrestor boards and enclosures are also available from Geokon. These units install
where the instrument cable exits the structure being monitored. The enclosure has a
removable top to allow the customer to service the components or replace the board in the
event that the unit is damaged by a lightning strike. A connection is made between the
enclosure and earth ground to facilitate the passing of transients away from the gage. See
Figure 10.
Plasma surge arrestors can be epoxied into the instrument cable, close to the sensor. A
ground strap then connects the surge arrestor to an earth ground, such as a grounding stake or
the rebar itself.
Consult the factory for additional information on available lightning protection.

Figure 10 - Lightning Protection Scheme