JLG 1850SJ Operation & Safety Manual page 144

Hide thumbs Also See for 1850SJ:
Table of Contents

Advertisement

Accessories
7.16.3
Welding Accessories
12 ft welding leads with clamp and stinger (stored in the platform)
Fire extinguisher
7.16.4
Safety Precautions
Do not overload platform.
De-rate the platform by 64 lb (29 kg) when welder is in the platform.
Check for cracked welds and damage to welder supports.
Check for proper and secure installation of welder and bracket.
Ensure no personnel are beneath platform.
Do not exit platform over rails or stand on rails.
Use this option only on approved models.
Keep lanyard attached at all times.
Ensure correct polarity of leads.
Wear proper welding apparel.
Use correct rod size and current settings.
Do not use electrical cords without ground.
Do not use electrical tools in water.
Do not weld to the platform.
Do not ground through the platform.
Do not use a high frequency arc starter with TIG welder.
7.16.5
Preparation and Inspection
Connect ground clamp to metal being welded.
Ensure there is a good ground connection and observe proper polarity.
144
WARNING
WARNING
31222393
1850SJ

Advertisement

Table of Contents
loading

Table of Contents