Graco Dyna-Star 77X202 Instructions Manual page 10

Pump system
Table of Contents

Advertisement

Installation
Motor Control Board
F
. 8
IG
Key
A
+ (Positive) Power Input
B
- (Negative) Power Input
C
Turn On Signal -
D
Turn On Signal +
E
Red (Fault) LED - Blinks type of fault (See Fault Table)
F
Green (Power) LED -
Blinks: Power ON, Pump running
Solid: Power/Pump OFF
G
Current Control Potentiometer (Minimum: Turn Knob
Counter-Clockwise / Maximum: Turn Knob Clockwise)
H
Flow Control Potentiometer (Minimum: Turn Knob
Counter-Clockwise / Maximum: Turn Knob Clockwise)
J
Pump Control Switch*
PWR - Turns pump on when power is applied
10
A
B
C
D
J
F E
K
L
G
H
SIG - Turns pump on when voltage is applied to:
- SIG IN -
- SIG IN +
K
Blue Motor Wire Connection
L
Yellow Motor Wire Connection
M
Green Motor Wire Connection
N
J5 Connector - Motor Hall Cable Connector
*NOTE: Be sure power to pump is OFF before switching
between the PWR and SIG modes.